摘要
介绍了蓄热室顶部测温补偿条件、补偿方法、选取条件和注意事项。当需要采取蓄顶测温补偿时,可以通过比较横墙和直行的均匀系数选择蓄顶测温补偿方案。对横墙均匀系数较好的炉号选择异侧补偿方法,其余选择同侧补偿方法。
The compensation condition,compensation method,selection condition and precaution of temperature measurement on top of coke oven regenerator were described.When the temperature measurement on top of regenerator is required to be compensated,the compensation proposal of temperature measurement on top of regenerator is selected by compensation of lateral temperature and longitudinal temperature uniform factor.For oven number with better uniform factor of lateral temperature,hetero-side compensation method is selected,for others,homo-side compensation method is selected.
出处
《燃料与化工》
2010年第5期16-17,20,共3页
Fuel & Chemical Processes
基金
国家863课题研发子项(2009AA063301)
关键词
蓄顶温度
理论模型
同侧补偿
异侧补偿