摘要
大亚湾核电厂辐射监视系统(KRT系统)的KRT007MA监测从冷凝器抽出的非冷凝抽取物的β活性,以探测蒸汽发生器的泄漏。由于冷凝器系统的原因,导致KRT007MA采样气体中含有水滴,造成KRT007MA通道频繁发生故障。通过调查分析,确定了故障的根本原因,并采取了针对性的改进措施,彻底解决了问题。
In Daya Bay nuclear Power plant, KRT007MA provide continuous monitoring of β activity level for condenser system to detect the leakage of generator. Due to the unnormal working status of condenser, the sampiing gas of KRT007MA contains water drips, which makes the channel alarm frequently. By the investigation and analysis, the root cause was found and improvement was adopt, which solved the problem.
出处
《核电子学与探测技术》
CAS
CSCD
北大核心
2010年第8期1082-1086,共5页
Nuclear Electronics & Detection Technology
关键词
核电厂
冷凝器
辐射
监测
改进
Nuclear power plant, Condenser, Radiation, Monitoring,improvement.