期刊文献+

红外热像仪MRTD自动检测方法研究 被引量:4

Research on Minimum Resolvable Temperature Difference Automatic Test Method of the Thermal Imaging System
下载PDF
导出
摘要 为了降低对红外热像仪最小可分辨温差(MRTD)检测的成本,对使用者一级的MRTD检测方法进行了研究,提出了一种基于FLIR92模型和BP神经网络的MRTD检测方法。该方法在兼顾检测精度的基础上,对检测条件和检测人员的要求大大降低,同时降低了检测成本,对降低红外热像仪的使用和维护成本具有重要意义。 For reducing the cost of testing the minimum resolvable temperature difference (MRTD) of the infrared thermal imaging system, a MRTD testing-method on user-level had been researched and a method based on FLIR92 model and BP neural net work had been put forward. This method reduces the requirement of experiment conditions and testing-man and also has a sufficient testing-precision. It has a important meaning on using and maintenance of the thermal imaging system.
出处 《红外技术》 CSCD 北大核心 2010年第9期509-512,共4页 Infrared Technology
关键词 最小可分辨温差 三维噪声模型 BP神经网络 MRTD自动检测 minimum resolvable temperature difference, 3-D noise, BP neural net work, MRTD automatic testing
  • 相关文献

参考文献8

  • 1Luke Scott, John D'Agostino. NVEOD FLIR92 Thermal Imaging System Performance ModeI[C]//SPIE, 1992, 1689: 194-203.
  • 2Vollmerhausen R, Driggers R.G. NVTherm: next generation night vision model[J]. Proc. IRIS Passive Sensor, 1999: 121-134.
  • 3Wolfgang Wittenstein, Raanan Gal. TRM3 progress report[C]//SPIE, 2000, 4130: 292-302.
  • 4马冬梅,胡明鹏,孙军月.凝视型红外光电成像系统主要参数的实验室测评分析[J].红外技术,2007,29(8):483-487. 被引量:13
  • 5E. E. Burroughs, G. O. Moe. Automated MRTD using boundary contour system, custom feature extractors and fuzzy ARTMAP[C]//SPIE, 1995, 2470: 274-287.
  • 6Luke Scott. Modeling staring thermal systems with FLIR92[C]//SPIE, 1993, 1969: 21-26.
  • 7董伟,郭颋,张伟.MRTD客观测量中四杆靶图像的特征提取[J].激光与红外,2002,32(2):104-106. 被引量:6
  • 8Junyue Sun, Dongmei Ma. Intelligent MRTD Testing for Thermal Imaging System Using ANN[C]//Proc. of SPIE, 2006, 6031.

二级参考文献21

共引文献17

同被引文献27

引证文献4

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部