摘要 基于配电系统控制和操作的需要,在配网设计中应合理考虑电源系统采用交流还是直流系统,交流电源系统应在外引电源的同时设计由进线侧电压互感器引接电源,并设置不间断电源保证交流电源系统可靠性。对直流电源系统采用的整流设备和蓄电池组应符合其技术要求,并注意直流微断配置原则。 According to the control and operation need on power supply system,a reasonable choice should be made in AC and DC power system in design of the distribution network.In AC electrical source system,connecting power from voltage transformer should be designed when it linked external power.And uninterrupted power supply should be set to ensure the reliability of AC power system.Rectifiers and storage cells should be up to the mustard in DC electrical source system,besides the configuration principles of DC subminiature circuit breaker should be al-so adverted.
作者 杨锋
机构地区 福建龙岩电业局
出处 《低压电器》 北大核心 2010年第15期48-51,共4页 Low Voltage Apparatus
关键词 配电系统 断路器 不间断电源 配置 power distribution system circuit breaker uninterrupted power supply(UPS) configure
  • 相关文献

参考文献3

  • 1IEC 60298-1990 额定电压1 kV以上至52 kV含交流金属外壳开关设备和控制设备[S].1990.
  • 2DL/T 404-2007 户内交流高压开关柜订货技术条件[S].2007.
  • 3GB 3906-2006 3.6-40.5 kV交流金属封闭开关设备和控制设备[S].2006.