摘要
文章对空气源热泵热水系统、地下水源热泵热水系统和三热源热泵热水系统进行对比分析。三热源热泵热水系统是空气源、污水源和能量回收联合热水系统,空气源热泵利用夜间谷电运行生产热水,午后洗浴废热能量回收后,污水源热泵在峰电下运行生产热水。火用评价结果表明,该系统稳定性好,运行成本低,年平均火用效率高,值得推广。
In this paper,air-source heat pump(ASHP) hot water system,groundwater source heat pump(GSHP) hot water system and three-heat-source hot water system(TSHS) are compared.The TSHS is a kind of hot water system consisting of air source,wastewater source and energy recycle,and it operates as follows: ASHP runs with valley electricity during night to produce hot water,then waste heat energy of bath recycles during afternoon,and wastewater-source heat pump(WSHP) runs with peak electricity to produce hot water.The result of exergy analysis shows that the TSHS runs at a steady course with low cost and high mean annual efficiency,which is worth promoting.
出处
《合肥工业大学学报(自然科学版)》
CAS
CSCD
北大核心
2010年第9期1299-1303,共5页
Journal of Hefei University of Technology:Natural Science
基金
沈阳中铁水源热泵机组性能试验装置研究资助项目(2009012361)
关键词
三热源热泵热水系统
火用评价
热力计算
节能
three-heat-source hot water system(TSHS)
exergy analysis
thermal calculation
energy-saving