期刊文献+

基于NEC单片机的压力变送器系统 被引量:2

New Design of Pressure Measuring System
下载PDF
导出
摘要 系统以NEC单片机为内核单元,将压力信号放大后送入单片机,采用过采样理论、分段线性化的方法对差压曲线进行采样,通过查表的方式获取压力值,并通过16位D/A和V/I外围电路将差压值转换为4~20 mA的电流,采用IIC接口将系统控制字和压力值存储与EEPROM中,并且通过IIC接口实时将压力数据显示在LCD上。测试结果表明,系统功耗低、精度高、便于携带、性能稳定、可靠性高。 NEC MCU is the system kernel.The signal was amplified,then sampled by A/D in the MCU.The system utilized over-sampling theory and linearization by separating segment methods to process data from A/D.Pressure is converted to 4~20 mA Current through D/A and V/I circuit.Configuration word and data measured were stored in EEPROM through IIC interface.At the same time,LCD displays the pressure.The test results demonstrate that,the new design system has the advantages of high accuracy,low power——consuming and so on.
出处 《仪表技术与传感器》 CSCD 北大核心 2010年第8期19-21,共3页 Instrument Technique and Sensor
关键词 NEC单片机 压力测量 分段线性法 NEC-microcomputer pressure-measurement linearization by separating segment
  • 相关文献

参考文献4

  • 1卞正岗.传感器和检测仪表的现状和发展趋势[J].可编程控制器与工厂自动化(PLC FA),2007(8):30-30. 被引量:1
  • 2张国雄,金篆芷.测控电路(B).北京:机械工业出版社,2000:184-191.
  • 3美国ALLSensors 传感器datasheet.www.allsensors.com.
  • 4袁涛.单片机C高级语言程序设计极其运用.北京:北京航空航天大学出版社,2001.