期刊文献+

新型牙种植体与颌骨结合情况的研究 被引量:1

EXPERIMENTAL STUDY OF NEW TYPE IMPLANT-BONE INTEGRATION
下载PDF
导出
摘要 目的:研究新型种植体与骨的结合情况。方法:选取成年狼狗6只,拔除其双侧下颌全部前磨牙3个月后每侧拔牙窝内种植新型种植体,对照组种植体各2枚,共48枚。术后1,2,3月分别处死2只犬。通过大体观察,X线片观察和扫描电镜观察种植体与颌骨结合情况。结果:2种种植体和骨界面X线表现相似,均无骨质破坏;3个月时,扫描电镜观察到二种种植体与新骨组织形成良好的骨结合,种植体表面骨沉积成板层状,骨和种植体直接接触。结论:新型种植体能与骨形成良好的骨性结合。 Objective:To study the implant-bone integration conditions of a new type tooth implant.Methods: All premolars in bilateral jaw of 6 adult dogs were removed.Three months later,two new type implants and two cylinder-implants as controle were implanted into the sockets of each side,altogether 48 implants.Every two dogs were sacrificed one,two and three months after surgery.The interface of the implant-bone were checked with radiograph and scanning electron microscopy. Results:X-ray showed that implant-bone interface had no bone absorption with two kinds of implant. In the third month, two kinds of implant and new bone become an integrate, bone deposited into lamellare in surface of implants. There is no stratum intermedium between bone and implant. Conclusion:The new type implant can form excellent implant-bone integrateion.
出处 《泸州医学院学报》 2010年第4期385-388,共4页 Journal of Luzhou Medical College
关键词 种植体 界面 扫描电镜 Implant Interface Scanning electron microscopy
  • 相关文献

参考文献4

  • 1张婷,夏海斌,王贻宁,彭聪,赵艳.中空种植体-骨间隙愈合界面的组织学观察[J].口腔医学研究,2007,23(5):485-487. 被引量:3
  • 2Esposito M,Lausmaa J,Hirsch JM,et al.Surface analysis of failed oral titanium implant[J].Journal of biomedical materials research,1999;48(4):559.
  • 3Nedir R,Bischof M,Szmukler MS,et al.Predicting osseo-integration by means of implant primary stability[J].ClinOral Implants Res,2004;15 (5):520.
  • 4Tanzer M,Kantor S,Bobyn JD.Enhancement to bone growth into porous intramedullary implants using non invasive low intensity ultrasound[J].orthop Res,2001;19(2):195.

二级参考文献14

  • 1Ogawa T, Nishimura I. Genes differentially expressed in titanium implant healing [ J]. J Dent Res, 2006, 85 (6):566 -570
  • 2Daniele B. Bone regeneration at implants with turned or rough surfaces in self - contained defects. An experimental study in the dog [ J ]. J Clin Periodontal, 2005, 32:448-455
  • 3Clemens JAM, Klein CPAT. Healing of large (2mm) gaps around calcium phosphate- coated bone implants: A study in goats with a follow -up of 6 months [ J]. J Biomed Mater Res, 1998, 40:341 -349
  • 4Cooper LF. Formation of mineralizing osteoblast cultures on machined, titanium oxide grit - blasted, and plasma - sprayed titanium surfaces [J]. lnt J Oral Maxillofac Implants, 1999, 14(1 ) : 37 - 47
  • 5Ogawa T, Nishimura I. Different bone integration profiles of turned and acid - etched implants associated with modulated expression of extracellular matrix genes [ J ]. Int J Oral Maxillofac Implants, 2003, 18 (2) : 200 - 210
  • 6Trisi P. Bone- implant contact on machined and dual acidetched surfaces after 2 months of healing in the human maxilla [ J ]. J Periodontol, 2003, 74 (7) : 945 - 956
  • 7Wennerberg A. A histomorphometric and removal torque study of screw- shaped titanium implants with three different surface topographies [ J ]. Clin Oral Implants Res, 1995, 6 ( 1 ) : 24 - 30
  • 8Weng D. Osseotite vs. machined surface in poor bone quality. A study in dogs [ J ]. Clin Oral Implants Res, 2003, 14 (6):703 - 708
  • 9Ogawa T. Biomechanical evaluation of osseous implants having different surface topographies in rats [ J]. J Dent Res, 2000, 79 (11):1857-1863
  • 10Baker D, London R, O' Neal R. Rate of pull - out strength gain of dual - etched titanium implants : a comparative study in rabbits [ J ]. Int J Oral Maxillofac Implants, 1999, 14(5 ) : 722 - 728