影响四角喷燃煤粉炉再热器汽温的因素分析及调整措施 被引量:2

Impact Tangentially Fired Pulverized Coal Reheater Steam Temperature Factors and Adjustemnt Measures
下载PDF
导出
摘要 针对某电厂一直存在再热器超温现象,减温水投入量较大,严重影响了锅炉的安全运行。通过现场试验,掌握了锅炉运行特性,详细的分析再热器管壁超温的原因主要受过量空气系数,火焰中心位置、燃料性质的影响较大,通过对机组的风煤配比,改变燃烧器摆角等可调参数的调节,改善了机组的超温报警现象,确保锅炉安全、稳定、经济运行。 There has been a power plant reheater over-heating phenomena,Reducing the amount of attempering water,seriously influences the safe operation of boiler,Throug on-sitee test,the operation characteristics of the boiler was known.Detailed analysis of the reheater temperature is due mainly to excessive air cofficient,the flame center,the fule properties.By adjusting the ratio of air-coal,changing the burner swing angle etc adjustable parameters,reduce the phenomena over-heatering,ensure the safe and economical operation of the boil.
作者 王贵林
出处 《电力学报》 2010年第3期239-241,共3页 Journal of Electric Power
关键词 锅炉 再热器 超温 减温水 boil reheater over-heater attempering water
  • 相关文献

参考文献3

  • 1金维强,涂仲光.电厂锅炉[M].北京:中国电力出版社,1997.
  • 2黄新元.电站锅炉运行与燃烧调整[M].北京:中国电力出版社,2002..
  • 3岑可法,周昊,池作和.大型电站锅炉安全及优化运行技术[M].北京:中国电力出版社,2002.

共引文献73

同被引文献16

引证文献2

二级引证文献2

相关作者