摘要
本文分析了制约热泵热水器最高出水温度的因素,进一步从理论上探讨了换热温差对出水温度的影响,并通过计算进行验证,其结果可为热泵热水器的设计提供一定的参考。
This paper analyzed the restriction factor of the heat pump water heater highest outlet temperature,has discussed the influence of the heat transfer temperature difference to the water leakage temperature theoretically,and carried on the confirmation through the computation,its result might provide certain reference for the design of the heat pump water heater.
出处
《科技广场》
2010年第7期177-179,共3页
Science Mosaic
关键词
热泵热水器
水温
换热温差
heat pump water heater
water temperature
heat transfer temperature difference