AAA算法与PBC算法在乳腺癌调强放疗计划中的比较研究 被引量:4

原文传递
导出
摘要 调强放疗能改善乳腺内剂量均匀度,减少乳腺周围正常组织受照剂量,降低正常组织晚期并发症概率。本研究应用瓦里安Eclipse治疗计划系统对乳腺癌病例进行调强放疗计划设计,并比较AAA算法与PBC算法对靶区剂量分布、心脏和肺受照剂量和体积之间的差异,现将结果报道如下。
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2010年第5期424-425,共2页 Chinese Journal of Radiation Oncology
  • 相关文献

参考文献5

  • 1徐晓娜,吴昊,韩树奎.左侧乳腺癌调强放疗的剂量学研究[J].中华放射肿瘤学杂志,2006,15(3):192-195. 被引量:40
  • 2Carlaprile P,Venencia CD,Besa P.Comparison between measured and calculated dynamic wedge dose distributions using the anisotropic analytic algorithm and pencil-beam convolution.J Appl Clin Med Phys,2006,8:47-54.
  • 3Bragg CM,Wingate K,Conway J.Clinical implications of the anisotropic analytical algorithm for IMRT treatment planning and verification.Radiother Onco1,2008,86:276-284.
  • 4Panettieri V,Barsoum P,Westermark M,et al.AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments.Phantom and breast case study with the Monte Carlo code penelope.Radiother Oncol,2009,93:94-101.
  • 5Fogliata A,Nicolini G,Vanetti E,et al.The impact of photon dose calculation algorithms on expected dose distributions in lungs under different respiratory phases.Phys Med Biol,2008,53:2375-2390.

二级参考文献9

  • 1Early Breast Cancer Trialists' Collaborative Group.Favourable and unfavourable effects on long-term survival of radiotherapy for early breast cancer:an overview of the randomized trials.Early Breast Cancer Trialists' Collaborative Group.Lancet,2000,355:1757-1770.
  • 2David L,Elizabeth J,Adams R,et al.Cardiac avoidance in breast radiotherapy:a comparison of simple shielding techniques with intensitymodulated radiotherapy.Radiother Oncol,2001,60:247-255.
  • 3Larry L,Michael B,Robert C,et al.Intensity modulation to improve dose uniformity with tangential breast radiotherapy:initial clinical experience.Int J Radiat Oncol Biol Phys,2000,48:1559-1568.
  • 4Vicent M,Trank A,Michael B,et al.Significant reductions in heart and long doses using deep insipiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation.Int J Radiat Oncol Biol Phys,2003,55:392-406.
  • 5Buchholz TA,Gurgoze E,Bice WS,et al.Dosimetric analysis of intact breast irradiation in off-axis planes.Int J Radiat Oncol Biol Phys,1997,39:261-267.
  • 6Solin LJ,Chu JCH,Sontag MR,et al.Three-dimensional photon treatment planning of intact breast.Int J Radiat Oncol Biol Phys,1991,21:193-203.
  • 7李平.心脏的放射损伤.见:申文江,王绿化.放射治疗损伤.北京:中国医药科技出版社,2001.104-114.
  • 8Gagliardi G,Lax l,Soderstrom S,et al.Prediction of excess risk of longterm cardiac mortality after radiotherapy of stage Ⅰ breast cancer.Radiother Oncol,1998,46:63-71.
  • 9Hong L,Hunt M,Chui C,et al.Inensity modulated tangential beam irradiation of the intact breast.Int J Radiat Oncol Biol Phys,1999,44:1155-1164.

共引文献39

同被引文献34

  • 1伍然,全红,徐利明.不同算法所得IMRT计划的剂量学验证评估[J].中国医学物理学杂志,2011,28(3):2581-2583. 被引量:7
  • 2张富利,王军良,盛洪国,郑明民.PBC算法与AAA算法在肺癌调强放疗中的剂量学比较[J].中国医学物理学杂志,2011,28(3):2588-2590. 被引量:11
  • 3Chung H, Jin H, Palta J, et al. Dose variations with varying calculation grid size in head and neck IMRT [J]. Phys Med Biol, 2006, 51 (19): 4841-4856.
  • 4Dempsey JF, Romeijn HD, Li JG, et al. A fourier analysis of the dose grid resolution required for accurate IMRT fluenee map opfimizaion [J].MedPhys, 2005, 32 (2): 380-388.
  • 5De Smedt B, Vanderstraeten B, Reynaert N, et al. Investigation of geometrical and scoring d resolution for Monte Carlo dose calculations for IMRT [J].Phys Med Nol, 2005, 50 (17):4005-4019.
  • 6Chung HT, Jin HS, Dempsey JF, et al. Evaluation of surface and build-up region dose for intensity modulated radiation therapy in head and neck cancer [J]. Med Phys, 2005, 32 (8): 2682-2689.
  • 7崔念基,卢泰祥,邓小武,等.临床放射肿瘤学[M].广州:中山大学出版社,2005:263-283.
  • 8Ezzell GA, Galvin JM, Low D, et al. Guidance document on delivery, treatment planning, and clinical implement of IMRT: Report of the IMRT subcommittee of the AAPM Radiation Therapy Comraittee [J].Med Phys, 2003, 30 (8): 2089 2115.
  • 9Liu HH, Wang X, Dong L, et al. Feasibility of sparing lung and other thoracic structures with intensity-modulated radiotherapy for non-small cell lung cancer [J]. Int J Radiat OneolBiolPhys, 2004, 58 (4):1268-1279.
  • 10van TRA, Mak CA, Moedand MA, et al. A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate [J]. Int J Radiat Oncol BiolPhys, 1997, 37 (3): 731-736.

引证文献4

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部