期刊文献+

Delayed type lllb endoleak using Anaconda^TM stent graft in abdominal aortic aneurysm repair

Delayed type lllb endoleak using Anaconda^TM stent graft in abdominal aortic aneurysm repair
原文传递
导出
摘要 Endoleaks are defined as the persistence of blood flow outside the lumen of the endoluminal graft but within an aneurysm sac or the adjacent vascular segment being treated by the graft and classified into 5 categories. Endoleaks are defined as the persistence of blood flow outside the lumen of the endoluminal graft but within an aneurysm sac or the adjacent vascular segment being treated by the graft and classified into 5 categories.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第18期2623-2624,共2页 中华医学杂志(英文版)
关键词 type endoleak endovascular aortic aneurysm repair COMPLICATION fabric tears type Ⅲ endoleak endovascular aortic aneurysm repair complication fabric tears
  • 相关文献

参考文献9

  • 1White GH,Yu W,May J.Endoleak-a proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft.J Endovasc Surg 1996; 3:124-125.
  • 2Veith FJ,Baum RA,Ohki T,Amor M,Adiseshiah M,Blankensteijn JD,et al.Nature and significance of endoleaks and endotension:summary of opinions expressed at an international conference.J Vasc Surg 2002; 35:1029-1035.
  • 3Wanhainen A,Nyman R,Eriksson MO,Bjoerck M.First report of a late type Ⅲ endoleak from fabric tears of a Zenith stent graft.J Vasc Surg 2008; 48:723-726.
  • 4Teutelink A,van der Laan MJ,Milner R,Blankensteijn JD.Fabric tears as a new cause of type Ⅲ endoleak with Ancure endograft.J Vasc Surg 2003; 38:843-846.
  • 5Van der Vliet JA,Blankensteijn JD,Kool LJ.Type Ⅲ endoleak caused by fabric tear of a Zenith endograft after low-pressure balloon modeling.J Vasc Interv Radiol 2005; 16:1042-1044.
  • 6Biebl M,Hakaim AG,Oldenburg WA,Klocker J,McKinney JM,Paz-Fumagalli R,et al.Management of a large intraoperative type Ⅲb endoleak in a bifurcated endografta case report.Vasc Endovasc Surg 2005; 39:267-271.
  • 7Teruya TH,Ayerdi J,Solis MM,Abou-Zamzam AM,Ballard JL,McLafferty RB,et al.Treatment of type Ⅲ endoleak with an aortouniiliac stent graft.Ann Vasc Surg 2003; 17:123-128.
  • 8Choke E,Thompson M.Endoleak after endovascular aneurysm repair:current concepts.J Cardiovasc Surg (Torino)2004; 45:349-366.
  • 9Baum RA,Stavropoulos SW,Fairman RM,Carpenter JP.Endoleaks after endovascular repair of abdominal aortic aneurysms.J Vasc Interv Radiol 2003; 14:1111-1117.