期刊文献+

某电厂再热器泄漏原因分析 被引量:1

Leakage Analysis of Reheater Tube of a Power Plant
原文传递
导出
摘要 某电厂2号锅炉水压试验发现末级再热器改造用TP347H管泄漏,对泄漏管段进行了裂纹宏观检查、化学成分分析、硬度测试和扫描电镜分析.结果表明,泄漏主要是应力腐蚀开裂导致的,针对火力发电厂提出了防止奥氏体不锈钢应力腐蚀开裂的措施. Leakage of TP347H secondary reheater tube occurred during an operating pressure hydrostatic test of unit 2 boiler in a power plant.The leakage tube has been examined by macroscopic inspection,chemical composition analysis,hardness tester and scanning electron microscope analysis. The result shows that the leakage is due to stress corrosion cracking of the TP347H tubes. Therafter,several measures are proposed to prevent such austenitic stainless steels from stress corrosion cracking.
出处 《腐蚀科学与防护技术》 CAS CSCD 北大核心 2010年第5期458-460,共3页 Corrosion Science and Protection Technology
关键词 应力腐蚀 奥氏体不锈钢 再热器 失效 stress corrosion cracking austenitic stainless steel reheater tube leakage
  • 相关文献

参考文献4

二级参考文献30

  • 1杨波,田松柏,赵杉林.不同形态硫化合物腐蚀行为的研究[J].腐蚀科学与防护技术,2004,16(6):385-388. 被引量:39
  • 2涂善东,戴树和.高温过程设备的寿命评价技术进展[J].压力容器,1996,13(2):151-158. 被引量:17
  • 3吴非文.火力发电厂高温金属运行.水利电力部高温金属运行[M].,..
  • 4-.关于高温持久强度外推方法及应用[M].冶金部沈阳金属研究所,..
  • 5岑可法 樊建人 池作和.锅炉和热交换器的积灰、结渣、磨损和腐蚀的防止原理与计算[M].科学出版社,1995..
  • 6F J Torres ect.Corrosion behavior of sensitized duplex stainless steel[J].Bio-Medical Materials and Engineering,1998,(8):25.
  • 7O V Kasparova.Peculiarities of intergranular corrosion of silicon-containing austenitic stainless steel[J].Protection of Metals,2004,(5):425.
  • 8E R Hwang,S G Kang.Intergranular corrosion of stainless steel in molten carbonate salt[J].Journal of Materials Science Letters,1997,(16):1387.
  • 9O V Kasparova.Intergranular corrosion of nickel alloys(Review)[J].Protection of Metals,2000,36(6):524.
  • 10A DI Schino,J M Kenney.Effect of grain size on the corrosion resistance of a high nitrogen-low nikelaustenitic steel[J].Journal of Materials Science Letters,2002,(21):1969.

共引文献171

同被引文献45

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部