期刊文献+

乙醇、甲醇、食用酒及工业酒精的拉曼光谱测定 被引量:16

Measurement of Ethanol, Methyl Alcohol, Industrial Alcohol and Edible Alcohol by Raman Spectroscopy
下载PDF
导出
摘要 利用拉曼光谱仪,对乙醇、甲醇、工业酒精及食用白酒作光谱分析,分析得知:甲醇与其它三者有不同的振动光谱,因而应可据此检查食用酒精中的甲醇.此外,在本文指定的组分前提下,可以根据水峰强度与乙醇(甲醇)特征峰的强度之比得出酒精含量。 The Raman spectra from ethanol, methyl alcohol, industrial alcohol and edible alcohol were measured and analyzed. It was found that methyl alcohol differ from other alcohol in vibrant spectroscopy, and three kinds of alcohol from different source have different Roman spectra. Basing on the intensity ratio of water Roman peak and the characterizing Roman peak of ethanol measured at the same time, one can quantitatively obtain the real alcohol concerns, hence providing a fast method for checking the fake drinks.
机构地区 云南工业大学
出处 《云南工业大学学报》 1999年第2期1-3,6,共4页
基金 云南工业大学校自立基金
关键词 乙醇 甲醇 食用酒 拉曼光谱 测定 工业酒精 Raman spectroscopy fake drink character peak Raman shift