介绍了华电灵武1号空冷机组的轴系特点,分析了调试期间低压转子4号、5号轴振异常振动的特点及原因,在低压转子联接短轴上加重后机组3000 r/min定速及带负荷过程中各轴承振动均小于50μm,达到优良水平。
The axis characteristics of unit 1 in Lingwu power plant are introduced.NO.4 and NO.5 bearing vibration characteristics and reasons are analyzed.After balance of LP short shaft,the bearing vibration is less than 50μm,the vibration reaches level A.