摘要
高压断路器是电力系统发电、输电、变电时,接通、分断电器和保护电路的主要设备,高压断路器的可靠运行,保障了电力系统安全稳定。而高压断路器液压机构作为其重要组成部分,成为断路器能否可靠运行的关键。就运行值班员发现运行中SW6高压断路器液压机构故障进行分析,提出相应的处理意见,有利于提高运行人员对此类故障的处理判断能力,以便更好地搞好电力安全生产。
The HV circuit breaker is the main equipment for connecting or breaking devices and protecting circuit of power system generation,transmission and transformation.HV circuit breakers ensure security and stability of power system,and HV circuit breakers hydraulic mechanism plays an important role in the breakers.The faults of SW6 HV circuit breakers hydraulic mechanism during operation are analyzed and some processing suggestions corresponding faults are advised,which is helpful to improve correcting faults abilities of operating personnel and to guarantee power safety production.
出处
《能源研究与管理》
2010年第3期50-52,共3页
Energy Research and Management
关键词
高压断路器
液压机构
故障分析
处理方法
HV circuit breaker
hydraulic mechanism
fault analysis
fault correction