摘要 目的评价64层螺旋CT冠状动脉造影对冠状动脉明显狭窄诊断的准确性和可行性。方法 109例冠心病疑似患者在1周内进行了64层CT冠状动脉造影及常规血管造影,对冠状动脉的主干及主要分支进行观察,以冠状动脉造影结果为金标准评价64层CT诊断冠状动脉狭窄的准确性。结果多层螺旋CT所显示的1296支冠状动脉中冠状动脉狭窄97处,正确诊断83处,漏诊3处,误诊14处。敏感性为96.5%,特异性为98.8%,阳性预测值为85.6%,阴性预测值为99.7%,准确率为98.7%.结论64层螺旋CT对冠状动脉狭窄诊断有较高的准确性,可作为高危人群普查筛选的首选方法之一。
作者 石宏 王朝军
出处 《基层医学论坛》 2010年第29期902-903,共2页 The Medical Forum
  • 相关文献

参考文献6

  • 1Ropers D,Baum U,Pohle K,et al.Detection of coronary artery stenoses with thin slice multi-detector row spiral computed tomography and multi-planar reconstruction[J].Circulation,2003,107(5):664-666.
  • 2Martuscelli E,Romagnoli A,D Eliseo A,et al.Accuracy of thin-slice computed tomography in the detection of coronary stenoses[J].Eur Heart,2004,25(12):1043-1048.
  • 3王怡宁,金征宇,孔令燕,张竹花,宋兰,张抒扬,张立仁,林松柏,王沄,赵文敏.64层与16层螺旋CT冠状动脉成像比较[J].中国医学科学院学报,2006,28(1):26-31. 被引量:44
  • 4Braunwald E.Unstable angina:an etiologic approach to management[J].Circulatian,1998,98(6):2219.
  • 5Matsumoto A,Kitamoto M,Imamura M,et al.Three-dimensional portography using multi-slice helical CT is clinical useful for management of gastic fundic varices[J].AJR,2001,178(4):899.
  • 6Nieman K,Cademartiri F,Lemos PA,et al.Reliable noninvasive coronary angiography with fast submillimeter multi-slice spiral computed tomography[J].Circulation,2002,106(16):2051-2054.

二级参考文献10

  • 1Ropers D,Baum U,Pohle K,etal.Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.Circulation,2003,107(5):664-666.
  • 2Mollet NR,Cademartiri F,Nieman K,etal.Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris.J Am Coll Cardiol,2004,43(12):2265-2270.
  • 3Martuscelli E,Romagnoli A,D'Eliseo A,etal.Accuracy of thin-slice computed tomography in the detection of coronary stenoses.Eur Heart J,2004,25(12):1043-1048.
  • 4Detre KM,Wright E,Murphy ML,etal.Observer agreement in evaluating coronary angiograms.Circulation,1975,52(6):979-986.
  • 5Flohr T,Stierstorfer K,Raupach R,etal.Performance evaluation of a 64-slice CT system with z-flying focal spot.Rofo,2004,176(12):1803-1810.
  • 6Nieman K,Cademartiri F,Lemos PA,etal.Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.Circulation,2002,106(16):2051-2054.
  • 7Mollet NR,Cademartiri F,Krestin GP,etal.Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography.J Am Coll Cardiol,2005,45(1):128-132.
  • 8Cademartiri F,Nieman K,van der Lugt A,etal.Intravenous contrast material administration at 16-detector row helical CT coronary angiography:test bolus versus bolus-tracking technique.Radiology,2004,233(3):817-823.
  • 9Hoffman U,Moselewski F,Cury RC,etal.Predictive value of 16-slice multidetector piral computed tomography to detect significant obstructive coronary disease in patients at high risk for coronary artery disease.Circulation,2004,110(17):2638-2643.
  • 10Schoepf UJ,Becker CR,Ohnesorge BM,etal.CT of coronary artery disease.Radiology,2004,232(1):18-37.

共引文献43

同被引文献20

引证文献3

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部