摘要
发现洁净绝缘表面电导随空气湿度变化时沿绝缘表面的工频电场分布有显著变化,并通过实验研究首次提出证实了沿面电场分布的这种变化对工频预放电以及工频闪络电压的影响。文中以大量的实验数据全面揭示了湿度对绝缘表面空气工频闪络电压影响的新机理,同时说明了“温度附加影响”的物理原因。
The results show that air humidity evidently affects the field distribution along clean insulating surfaces by the surface conductivity and it was confirmed that this effect of humidity will lead to the variation of both predischarge and flashover when AC voltage is applied .The paper proposed a new mechanism of humidity effect on AC flashover voltage and clarified so called “additional influence of temperature”.
出处
《中国电机工程学报》
EI
CSCD
北大核心
1999年第5期53-58,共6页
Proceedings of the CSEE
基金
国家自然科学基金