摘要 针对洗浴废水余热利用率低的现状,就如何提高废水余热利用率,提出了洗浴废水余热回收利用改造方案.分析了废热回收的利用效率及经济性,以及浴池余热回收和利用中需要解决的技术问题,给出了相应的解决方案.采用该方案可减少燃气燃料40%,节省运行费用30%. According to the problem of low waster heat usage of bath, a utilization and alteration solution of waste heat is proposed, the efficiency and economy of waste heat recovery and utilization, and the technical problems that need to be resolved during its usage and recovery, are analyzed. In consequence, the program can reduce 40% of gas fuel and save 30% of operating cost.
出处 《西安工程大学学报》 CAS 2010年第5期591-594,共4页 Journal of Xi’an Polytechnic University
关键词 废热 回收利用 浴池废水 节能 waste heat recovery and utilization wastewater bath energy-saving
  • 相关文献

参考文献12

  • 1张群力,王晋.地源和地下水源热泵的研发现状及应用过程中的问题分析[J].流体机械,2003,31(5):50-54. 被引量:61
  • 2HATTEN M J.Ground water heatpumping:lessons learned in 43 years at one building[J].ASHRAE Transactions,1992,98(1):1 031-1 037.
  • 3龚宇烈,赵军,李新国,等.地源热泵在美国工程应用及其发展[C]//全国热泵和空调技术交流会议论文集.北京:中国建筑工业出版社,2001:249-253
  • 4DONALD J Kroeker,CHEWING Pay C.Heat pump in an office building[J].ASHBA Transactions,1948,54:221-238.
  • 5DONALD J Kroeker,CHEWING Bay C.Costs of operating the beat pump in the equitable building[J].ASHRAE Transactions,1954,60:157-176.
  • 6KNIPE E C,RAFFERY K D.Corrosion in low temperature geothermal application[J].ASHRAE Tramactions,1985,91(2B-1):81-91.
  • 7RAFFERY Kevin.A capital cost comparison of commercial ground-source heat pump system[J].ASHRAE Transactions,1995,101(2):1 095-1 100.
  • 8中国工程建设标准化协会.建筑给水排水设计规范[S].北京:中国建筑工业出版社,2007.
  • 9美的空调股份有限公司.空气能热泵热水机技术手册(商用系列)(JZ-07-07A)[Z].美的空调股份有限公司,2008.
  • 10美的空调股份有限公司.美的水源热泵设计技术手册[R].美的空调股份有限公司,2009.

二级参考文献3

共引文献62

同被引文献21

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部