期刊文献+

二极管反向饱和电流的实验研究

Experimental Study on Diode Reverse Saturation Current
下载PDF
导出
摘要 利用直流复射式检流计代替电流表测量电流,采用分压式二极管反向饱和电流测试电路测量电压,对二极管反向饱和电流的测量与二极管反向饱和电流随温度变化之间的关系进行了实验研究。利用直流复射式检流计提高了测量精度,采用分压式二极管反向饱和电流测试电路便于控制电压的变化,可以更细微地观察反向电流的变化,从而较准确测得反向饱和电流值。 The current is measured using DC re -launched type galvanometer instead of ammeter ,the voltage is measured using the test ciruit of diode's reverse saturation current with partial pressure,the measurement of diode's reverse saturation current and the relationship between diode's reverse saturation current and the varying of temperature are studied by using experiments. The measurement precision is improved using DC relaunched type galva-nometer,the varying of voltage is controlled easily using the test circuit of diode's reverse saturation current with partial pressure,the varying of reverse saturation current is observed imperceptibility,the value of reverse saturation current is measured accurately.
出处 《延安大学学报(自然科学版)》 2010年第3期52-55,共4页 Journal of Yan'an University:Natural Science Edition
关键词 二极管 反向饱和电流 反向偏置电压 温度 diode reverse saturation current reverse bias voltage temperature
  • 相关文献

参考文献3

  • 1杨述武.普通物理实验(二电磁学部分)[M].北京:高等教育出版社,1985.46
  • 2孙新义.伏安法测二极管反向饱和电流的讨论.物理实验,1989,.
  • 3杨德甫,杨能勋,宋蓓.二极管反向饱和电流取值的实验分析[J].延安大学学报(自然科学版),2007,26(1):35-37. 被引量:3

二级参考文献3

  • 1杨述武.普通物理实验(二电磁学部分)[M].北京:高等教育出版社,1985.46
  • 2孙新义.伏安法测二极管反向饱和电流的讨论.物理实验,1989,.
  • 3电子线路教材编辑组.电子线路(上册)[M].北京:人民教育出版社,1980.5

共引文献3