摘要 研究三点法测量圆度时测头的读数误差及角位置误差时圆度测量精度的影响。从三点法的原理出发对测量过程进行误差分析,导出了圆度测量误差方程,并通过计算机仿真详细研究了测头的读数及角位置误差对圆度测量精度的影响。圆度测量精度主要决定于读数误差;如果3个测头间的夹角选择不当,将使测头读数误差在某些谐波上被大大放大。必须恰当选择3个测头间的夹角,使读数误差对圆度各次谐波测量结果的影响都较小。 Aiming at studying the effect of the reading error and the misalignment of the probes on the accuracy for roundness measurement with three-pointmethod, based on the principle of three-point methodand a thorough error analysis on the measurement process, the equation of roundness measurement error is derived. Also the effect of the reading errors and the angular misalignments of the probes on the accuracy forroundness and all the harmonics measurements has beenanalyzed in detail by computer simulation. The accuracyof roundness measurement is dominated by the readingerrors of the probes. If the angular positions of the threeprobes were arranged impr0perly. it might make thereading err0rs over amplified at some harmonics 0froundness. In 0rder to impr0ve the accuracy for round-ness measurement by three - point method, the anglesbetween three probes must be optimized,so that the ef-fect of the reading errors and the angular misalignmentson the accuracy for the measurements of all harmonics ofroundness could be minimized.
出处 《中国机械工程》 EI CAS CSCD 北大核心 1999年第5期534-537,共4页 China Mechanical Engineering
关键词 三点法 圆度 测量精度 读数误差 角位置误差 three-point method roundness measurement accuracy reading error the angular position error
  • 相关文献

参考文献4

  • 1青本保雄 大园成夫 等.-[J].精密机器(日),1966,32(12):831-836.
  • 2加藤秀雄 野村雄二郎 等.-[J].精密工学会志,1990,56(12):2303-2308.
  • 3朱永生.实验物理中的概论与统计[M].北京:科学出版社,1991.87-102.
  • 4朱永生,实验物理中的概率和统计,1991年,87页

同被引文献70

引证文献10

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部