期刊文献+

标准火灾下轴压型钢混凝土柱抗火性能研究 被引量:3

A Study on the Fire Resistance of Steel Reinforced Concrete Axial Compressive Columns under Standard Fire
下载PDF
导出
摘要 进行了1根标准火灾下轴压型钢混凝土柱的抗火性能试验。试验采用恒载升温的试验方法,炉温采用ISO-834标准升温曲线。测量了试件内部的温度场和试件轴向位移随时间的变化曲线,了解了试件的破坏过程。试验结果表明:混凝土爆裂对截面温度场分布、构件变形和耐火极限有较大的影响;截面温度场分布基本对称,温度沿构件纵向分布略有差别;试件经历了初始膨胀变形阶段、材料随温度升高而降低导致的变形发展阶段和变形急剧增加的破坏阶段。 The fire resistance of the 1 axial compressive steel reinforced concrete(SRC) column under the stan-dard fire was tested.The method of the temperature elevating with constant load was used throughout the experi-ment,and the heating was applied and controlled according to the standard ISO-834 temperature curve.The in-ner temperature field and the change curve of the axial displacement with time and damage procedure of the specimen were observed,the process of the specimen damaging was learned.The results show that the concrete spoil has largely influenced the temperature field distribution of the cross sections,deformation of the specimen and the degree of the fire resistance.The temperature field of the cross section was basically symmetrical,and the temperature distribution in the vertical component was slightly different.The deformation of SRC columns experi-enced three stages: the initial deformation while inflating,the development of deformation while the material de-creases with temperature increasing,and the damage stage with the dramatic increasing in deformation.
出处 《苏州科技学院学报(工程技术版)》 CAS 2010年第3期36-39,共4页 Journal of Suzhou University of Science and Technology (Engineering and Technology)
基金 国家自然科学基金项目(50708062) 苏州科技学院研究生科研创新计划资助项目(2009-06-24)
关键词 型钢混凝土柱 温度场 抗火性能 steel reinforced concrete columns temperature field fire resistance
  • 相关文献

参考文献6

二级参考文献13

  • 1钮宏,同济大学学报,1990年,18卷,3期
  • 2过镇海,1989年
  • 3过镇海,建筑结构学报,1982年,2期
  • 4李华东,硕士学位论文,1994年
  • 5李卫,建筑结构学报,1993年,14卷,1期
  • 6时旭东,博士学位论文,1992年
  • 7Lie T T,Irwin R J.Method to calculate the fire resistance of reinforcement concretecolumns with rectangular cross section[J].ACI Structure Journal,1993,90 (1):52-60
  • 8Kodur V K R,McGrath R.Fire endurance of high strength columns[J].Fire Technology,2003,39:73-87
  • 9Kodur V K R,Cheng F P,Wang T C,et al.Effect of strength and fiber reinforcement on fire resistance of high strength columns[J].Journal of Structure and Engineering,2003,129(2):253-259
  • 10Kodur V K R.Spalling in high strength concrete exposed to fire:concerns,causes,critical parameters and cures[C]//Proceedings,ASCE Structures Congress.Philadelphia,USA,2000

共引文献342

同被引文献32

  • 1蒋东红,李国强,王世伟,张彬.钢骨混凝土轴压柱抗火极限承载力计算[J].钢结构,2005,20(6):87-91. 被引量:10
  • 2郑永乾,韩林海.钢骨混凝土柱的耐火性能和抗火设计方法(I)[J].建筑钢结构进展,2006,8(2):22-29. 被引量:21
  • 3蒋东红,李国强,张彬.钢骨混凝土偏压柱抗火极限承载力分析研究[J].建筑钢结构进展,2006,8(2):55-62. 被引量:10
  • 4郭健,何益斌,郦世平,周海兵,田雁新.基于刚度退化的框架结构受力性能研究[J].湖南大学学报(自然科学版),2007,34(5):20-23. 被引量:7
  • 5宋天诣,韩林海,经建生.型钢混凝土柱耐火性能的实验研究[C].第四届全国钢结构防火及防腐技术研讨会暨第二届全国钢结构抗火学术交流会.上海,中国,2007:158-172.
  • 6Malhotra HL, Stevens RF. Fire resistance of encased steel stan- chions [C]/ /. Proceedings of the Institution of Civil Engineers ICE, 1964: 77-97.
  • 7Wang ZH, Tan KH . Residual area method for heat transfer analy sis of concrete-encased I sections in fire[J]. Engineering Struc tures, 2006, 26(3): 411-422,.
  • 8Jiang-Tao Yu, Zhou-Dao Lu, Qun Xie. Nonlinear analysis of SRC columns subjected to fire [J]. Fire Safety Journal, 2007,42 (1) : 1 - 10.
  • 9Young B, Ellobody E. Performance of axially restrained concrete encased steel composite columns at elevated temperatures [J]. En gineering Structures, 2011, 33(1): 245-254.
  • 10T T Lie. Fire resistance of rectangular steel columns filled with bar-reinforced concrete [J]. Journal of Structural Engineering, 1994,120(5) :1489-1509.