期刊文献+

RESD-1人体静电放电模型系统设计与研究 被引量:2

Design and Study on RESD-1 Human Body ESD Model System
下载PDF
导出
摘要 根据"Sandia严格人体模型"的电路参数设计制作了RESD-1人体静电放电模型系统,对XX雷管和XX电爆管ESD进行了静电安全性实验研究.实验中考虑了火工品经低湿储存、多次静电刺激、在低湿条件下接受静电刺激以及经由脚-脚和脚-壳方式放电等多种因素对其静电安全性的影响.初步的实验结果表明,在军用武器的正常拆装过程中,XX雷管和XX电爆管均具有较高的静电安全性. RESD-1 human body electrostatic discharge model system,based on "Sandia strict human body model",was designed and manufactured.Electrostatic security experiments were carried out for the certain detonator and electronic detonator ESD.There were many factors,such as low humid stockpile,frequent static stimulation,static stimulation at low humid,foot to foot and foot to shell discharge,for the explosive to be considered for the infection of static security.Elementary experiments showed that the certain detonator and electronic detonator had better static security in the military weapon assembly and disassembly.
出处 《河北大学学报(自然科学版)》 CAS 北大核心 2010年第5期600-603,共4页 Journal of Hebei University(Natural Science Edition)
基金 国家总装预研基金资助项目(9140A11060608ZW0301)
关键词 火工品 严格人体模型 静电安全性 explosive strict human body model static security
  • 相关文献

参考文献2

  • 1朱长清,刘尚合,魏明.静电放电模拟器放电回路的设计[J].仪表技术与传感器,2004(3):31-33. 被引量:9
  • 2刘尚合.静电放电及静电防护的研究与进展[M]//徐匡迪,编.中国科学技术前沿(中国工程院版第6卷).北京:高等教育出版社,2003:167-202.

二级参考文献7

  • 1International standard IEC61000-4-2,Edition1.2.2001.
  • 2DAVID P,MARTIN A.ESD:waveform calculation,field and current of human and simulator ESD.J.Electrostatics,1996(38):31.
  • 3KANAGAWA.ESD simulator ESS series brochure.Noise Laboratory Co.,Ltd.,Japan.
  • 4International standard IEC61000-4-2,Edition1.2.2001.
  • 5DAVID P,MARTIN A.ESD:waveform calculation,field and current of human and simulator ESD.J.Electrostatics,1996(38):31.
  • 6KANAGAWA.ESD simulator ESS series brochure.Noise Laboratory Co.,Ltd.,Japan.
  • 7魏明,刘尚合,武占成,陈亚洲.ESD模拟器电流校验研究[J].仪表技术与传感器,1999(3):19-21. 被引量:4