摘要 针对目前机织涤纶人造血管的顺应性较低问题,采用聚对苯二甲酸丙二醇酯(PTT)纤维作为纬纱用材料,织制了机织人造血管用织物,并且测试了织物的力学性能。结果显示,用PTT纬纱织制的机织人造血管用织物,其初始模量大大低于PET织物,且弹性回复率好。在自行研制的血管顺应性仿真测试仪上评价了PET和PTT管状织物的顺应性。结果表明,在相同的脉冲压力作用下,PTT长丝制成的人造血管具有良好的径向顺应性,较符合人体内血管的直径/压力变化特征。 In view of the low radial compliance of the current woven artificial blood vessels made of polyester(PET),polytrimethylene terephthalate(PTT) filament yarns are used as the weft in manufacturing artificial blood vessels.Tensile tests show that the initial modulus of the woven fabrics made of PTT filaments is much lower than that of common used PET filaments.In addition,the former shows much better property of elastic recovery than the latter.The radial compliance of woven artificial blood vessels made of PTT and PET filaments is tested respectively on a newly developed compliance tester.The results show that,under the same pulse pressures,PTT woven artificial blood vessel has good radial compliance and is more suitable to meet the requirements of the body blood vessel in diameter-pressure variation.
出处 《纺织学报》 EI CAS CSCD 北大核心 2010年第10期20-23,共4页 Journal of Textile Research
基金 高等学校学科创新引智计划资助项目(B07024) 苏州大学丝绸工程重点实验室开发项目(KJS0915)
关键词 顺应性 PTT纤维 机织人造血管 织物模量 compliance PTT filament woven artificial blood vessel fabric modulus
  • 相关文献

参考文献9

  • 1KLABUNDE R E.Cardiovascular Physiology Concepts[M].Ohio:Oste M Co,2002:4-5.
  • 2MOGHE A K.Study and characterization of small diameter woven tubular fabrics[D].MSc Thesis Raleigh:North Carolina State University,2002:6-11.
  • 3王璐,丁辛,Durand Bernard.人造血管的生物力学性能表征[J].纺织学报,2003,24(1):7-9. 被引量:29
  • 4KANTSEVITCHA V,MASTEIKO E,RIBICKIS L.Vascular prosthesis:US,20040221623[P].2004-11-11.
  • 5GUPTA B S,KASYANOV V A.Biomechanies of human ccmmon carotid artery and design of novel hybrid textile compliant vascular grafts[J].Journal of Biomedical Materials Research,1997,34(9):341-349.
  • 6MOGHE A K,GUPTA B S.Small-diameter blood vessels by weaving:prototyping and modeling[J].Journal of the Textile Institute,2008,99(5):467-477.
  • 7王璐,姜华,杜令洋,等.人造血管顺应性仿真测试装置及其测试方法:中国,101393095[P].2009-03-25.
  • 8邹菲,王璐.高分子材料人造血管顺应性的研究[J].医用生物力学,2004,19(3):188-192. 被引量:6
  • 9KANNANA Y R,SALACINSKIA H J,ODLYHAB M,et al.The degradative resistance of polyhedral oligomeric silsesquioxane nanoeore integrated polyurethanes:an in vitro study[J].Biomaterials,2006,27(5):1971-1979.

二级参考文献36

  • 1[1]How T V et al. Engineering Design of Vascular Prosthesis. Proc Instn Mech Engra, 1992(206): 61 ~ 69.
  • 2[2]King M W. Designing Fabrics for Blood Vessel Replacement. Canadian Textile Journal, 1991 (4): 24 ~ 30.
  • 3[3]Guidoin R.. Textile Arterial Prostheses: Is Water Permeability Equivalent to Porosity? J. Biomed. Mater. Res., 1987(21) :65~ 87.
  • 4[4]ISO7198. Cardiovascular Implants - Tubular Vascular Prostheses, 1998.
  • 5[5]Wang L. Contribution a l' etude du Vieillissement des Protheses Vasculaires Textiles. Doctral Thesis, University of Haute Alsace. France, 2001.
  • 6[6]Savvides C N et al. Numerical Analysis of the Flow Through a Corrugated Tube with Application to Arterial Prostheses. J Fluid Mech, 1984(138): 129~160.
  • 7ISO7198, Cardiovascular Implant - Tubular Vascular Prostheses, [ S ]. 1998.
  • 8Conti JC, Strope ER, Price KS, et al. Sources of error in monitoring high speed testing of vascular grafts [ J ]. Biomedical Sciences Instrumentation, 1998,34 (4): 240 - 245.
  • 9Klabunde RE. Cardiovascular Physiology Concepts [ M ]. Ohio: Oste M Co. 2002.4 - 5.
  • 10Conti JC. Dynamic Compliance Tester [ P]. USA. 1990.