3A住宅楼板隔声设计与施工 被引量:4

Design and Construction of Sound Insulation in the 3A Residence Building
下载PDF
导出
摘要 目前商品住宅楼板不经处理很难达到一级隔声指标要求,而住宅中楼板隔声性能符合要求是达到3A住宅性能认定的必要条件。项目中住宅客厅采取橡胶颗粒隔声施工方案,卧室采用黏结胶改性隔声施工方案,通过正确选材、合理施工,避免声桥,现场声学测试的楼板隔声指标均达到3A住宅的隔声设计标准,这些对楼板隔声施工提供了工程范例。 The sound reduction index of high-quality residence building can hardly attain requirement without sound insulation processing.It’s essential condition for the building slab to meet sound reduction index to attain 3A residential building.The living room ground brick adopts rubber grain and the bedroom adopts glues knot gum to raise sound insulation properties in the construction project.It’s important to properly choose materials,reasonable construction,avoide sound bridge in construction process.The spot sound test reveals that floor slab construction satisfied the sound reduction class which provided an example to the building plank.
作者 王军强 黄新
出处 《施工技术》 CAS 北大核心 2010年第10期120-122,共3页 Construction Technology
基金 江苏省建筑业科研项目(JGJH2009-09)
关键词 高品质住宅 隔声量 施工 撞击声 high-quality residence building sound reduction index construction impact sound