期刊文献+

Analysis of Vitamin K_3 by a Fluorescent Spectroelectrochemistry Method 被引量:3

Analysis of Vitamin K_3 by a Fluorescent Spectroelectrochemistry Method
下载PDF
导出
摘要 A simple and sensitive spectroelectrochemistry method for the determination of vitamin K3 was developed by combining electrolysis and fluoremetry. This method was based on that vitamin K3 was reduced at a glassy carbon electrode, and its product with characteristic fluorescence at 420 nm was determined with excitation wavelength at 309 nm. Under optimized electrochemical reaction conditions and fluorescent experiment parameters, the fluorescence intensity was proportional to the concentration of vitamin K3 in a range from 3.50×10^-7 to 1.05×10^-5 mol/L with a correlation coefficient of 0.9991, and detection limit was estimated to be 7.50× 10^-8 mol/L at a signal/noise ra- tio of 3. The relative standard deviation was less than 4.3%(n=5) and the recovery was in a range of 97%-105% for the determination of vitamin K3 in pharmaceutical preparations. The result is satisfactory for the determination of vitamin K3 as comparison to that from HPLC method. A simple and sensitive spectroelectrochemistry method for the determination of vitamin K3 was developed by combining electrolysis and fluoremetry. This method was based on that vitamin K3 was reduced at a glassy carbon electrode, and its product with characteristic fluorescence at 420 nm was determined with excitation wavelength at 309 nm. Under optimized electrochemical reaction conditions and fluorescent experiment parameters, the fluorescence intensity was proportional to the concentration of vitamin K3 in a range from 3.50×10^-7 to 1.05×10^-5 mol/L with a correlation coefficient of 0.9991, and detection limit was estimated to be 7.50× 10^-8 mol/L at a signal/noise ra- tio of 3. The relative standard deviation was less than 4.3%(n=5) and the recovery was in a range of 97%-105% for the determination of vitamin K3 in pharmaceutical preparations. The result is satisfactory for the determination of vitamin K3 as comparison to that from HPLC method.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第5期742-745,共4页 高等学校化学研究(英文版)
基金 Supported by the National Nature Science Foundation of China(No.20635020) the Open-end Fund of State Key Labo-ratory of Fine Chemicals, China(No.KF0508)
关键词 SPECTROELECTROCHEMISTRY FLUORESCENCE Electro-reduced Vitamin K3 Spectroelectrochemistry Fluorescence Electro-reduced Vitamin K3
  • 相关文献

参考文献15

  • 1Sarin S. K., Kumar M., Garg S., Hissar S., Pandey C., Sharma B. C., J. Gastroen. & Hepatol., 2006, 21, 1478.
  • 2Bai F. Y., Li X. T., Zhu G. S., Xing Y. H., Zeng X. Q., Ge M. F., Chem. J. Chinese Universities, 2009, 30(10), 1919.
  • 3Sastry C. S. P., Singh N. R., Reddy M. N., Sankar D. G., Int. J. Pharmaceutics, 1987, 39, 137.
  • 4Abdollahi H., Bagheri L., Anal. Chim. Acta, 2004, 514, 211.
  • 5Chen B. F., Zhao X. Y., GB/T 18872-2002, Standards Press of China, Beijing, 2003.
  • 6Song J. F., He P., Guo W.,Anal. Lett., 2001, 34, 1677.
  • 7Liu Z., Li T., Li J., Wang E,, Anal. Chim. Acta, 1997, 338, 57.
  • 8Wang L. Z., Ma C. S., Zhang X. L., Xu Y., Microchem. J., 1994,50,101.
  • 9Vire J. C., EI-Maali N. A., Patriarche G. J., Christian G. D., Talanta, 1988, 35, 997.
  • 10Somer G., Do,an M., Bioelectrochemistry, 2008, 74, 96.

同被引文献34

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部