摘要
利用EXCEL表编制了直埋供热管道纵向稳定性验算表,计算了在满足直埋供热管道纵向稳定性验算条件下的管道最小埋深,分析了管道埋深对补偿器、弯头设计选型的影响。
The checking calculation table for longitudinal stability of directly buried heat-supply pipeline is established by Excel table. The minimum pipeline depth meeting the checking calculation of longitudinal stability of directly buried heat-supply pipeline is calculated. The influence of pipeline depth on lectotype of compensator for thermal expansion and bend is analyzed.
出处
《煤气与热力》
2010年第10期14-16,共3页
Gas & Heat
关键词
直埋供热管道
管道埋深
补偿器
弯头
directly buried heat-supply pipeline
pipeline depth
compensator for thermal expansion
bend