摘要 本实验定量研究螺旋神经元耳毒性变性消失后分布的现象,供人工耳蜗极阵设计用。耳蜗光镜神经元计数结果显示:神经元存活数指向蜗顶的非线性增长,电极排列应作相应得非等距排列。临床人工耳蜗植入验证语音辨别力提高65%。 The objective of the experiment is to estimate subsequent to ototoxicity quantitatively the number and distribution of neuron remaining in the spiral ganglion for improving the electrode array of cochlear implant. The counts of residual neuron was assessed in a series of section under light microscopy. The resulting indicates that a non-linearity growing of survivor towards the apex and new non-equadistance of electrode array is recommended. Clinical trials reveals the 65% intelligibility scores was obtained with the nwe non-equadistance of electrode array in 11 cases of profound deafness.
出处 《上海生物医学工程》 1999年第2期3-6,40,共5页 Shanghai Journal of Biomedical Engineering
关键词 螺旋神经节 神经元 极阵 耳蜗植入 重聋 Spiral ganglion Neuron Electrode array Cochlear implantation
  • 相关文献

同被引文献12

  • 1Neises GR, Mattox DE, Oulley RC. The maturation of the end bulb of Held in the rat anteroventral cochlear nucleus. Anat Rec, 1982,204:271 - 279
  • 2Leake PA, Kuntz AL, Moore CM, et al. Cochlear pathology induced by aminoglycoside ototoxicity during postnatal maturation in cats.Hear Res, 1997,113(1-2) :117 - 132
  • 3Dorman MF, Loizou PC, Rainey D. Simulating the effect of cochlear-implant electrode insertion depth on speech understanding.J Acoust Soc Am, 1997, 102(5 Pt1):2993 -2996
  • 4Helms J,Muller J. [Selection of a cochlear implant and results of implantation]. Laryngorhinootologie, 1999,78( 1 ) : 12 - 13
  • 5Lenarz T, Battmer RD, Lesinski A, et al. Nucleus double electrode array: a new approach for ossified cochleae. Am J Otol, 1997,18(6 Suppl) : S39 - 41
  • 6Gstoettner W, Franz P, Hamzavi J, et al. Intracochlear position of cochlear implant electrodes.Acta Otolaryngol Stockh, 1999,119(2) :229 - 233
  • 7Rebscher SJ, Heilmann M, Bruszewski W, et al. Strategies to improve electrode positioning and safety in cochlear implants.IEEE Trans Biomed Eng, 1999,46(3) :340 - 352
  • 8Colletti V, Fiorino G. New window for cochlear implant insertion. Acta Otolaryngol Stockh, 1999,119(2) :214 - 218
  • 9Leake PA, Snyder RL, Hradek GT, et al. Chronic intracochlear electrical stimulation in neonatally deafened cats: Effects of intensity and stimulating electrode location. Hear Res, 1992;64:99 - 117
  • 10王德辉,王正敏.庆大霉素致豚鼠前庭毛细胞破坏后再生及功能恢复[J].中华耳鼻咽喉科杂志,1997,32(3):153-156. 被引量:3

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部