期刊文献+

辉光放电发射光谱法测定纯净钢中磷含量的不确定度评定 被引量:2

Evaluation of the Uncertainty for Measurement of Phosphorus in Clean Steel by Glow Discharge Optical Emission Spectrometry
下载PDF
导出
摘要 磷元素的激发波长短,纯净钢中磷元素的百分含量低,准确测量存在一定难度。通过辉光放电发射光谱法对纯净钢中磷元素含量进行测定。对测定过程中分析不确定因子进行相应不确定度的评定和计算,找出影响结果最大的不确定因素。评定结果表明,辉光放电发射光谱法测定纯净钢中磷元素含量能满足分析准确度的要求,可应用于中低合金钢中低含量磷元素的快速定量分析。 The phosphorus element excitation wavelength was quite short.The phosphorus element content was lowin the clean steel,So it was difficult to accurately measure. Through the glow discharge optical emission spectroscopy method to analysis the phosphorus element content in clean steel. Evaluate the uncertainty of analysis process and carried on the corresponding computation,discover the biggest impact factor. The evaluation results indicated that the glow discharge optical emission spectroscopy method to analysis phosphorus element content in the clean steel meet the analysis accuracy request,which could be used in lowphosphorus element content of middle and low-alloy steel rapid quantitative analysis.
作者 邓军华
出处 《福建分析测试》 CAS 2010年第4期65-67,71,共4页 Fujian Analysis & Testing
关键词 不确定度 不确定评定 辉光放电发射光谱法 纯净钢 uncertainty uncertainty evaluation phosphorus glowdischarge optical emission spectrometry clean steel
  • 相关文献

参考文献3

共引文献22

同被引文献425

引证文献2

二级引证文献17

相关作者