期刊文献+

空冷岛散热管外壁结垢的原因分析 被引量:2

Analysis on the Causes of Scale Formation on the Surface of Air Cooling Pipe
下载PDF
导出
摘要 针对武乡和信发电有限公司1号机组空冷岛外壁上结有不均匀白垢的问题,通过对现场设备、环境的考察及对垢样成份的能谱试验分析,得出管子外部积聚的飞灰经内部喷雾水溶解后,游离出的强碱性物质腐蚀了散热管子表面的镀锌层,形成了白垢,提出了减缓或避免进一步结垢的建议。 The white scale formation on the surface of air cooling pipe of Unit1 of Wuxiang Hexin Power Generation Co.,LTD arouses attentions.The inspections on the equipment,environment and the energy spectra analysis on the sample of scale lead to the conclusion that the scale is formed by the following reasons: the coal ash outside the pipe surface is dissolved by the water sprayed inside,therefore,the alkaline substances dissociated make the Zinc coating corroded,thus scale being formed.In this paper,suggestions are made to slow down or even avoid the scale formation.
出处 《山西电力》 2010年第5期35-36,共2页 Shanxi Electric Power
关键词 电厂 空冷岛散热管 结垢 power plant air cooling pipe scale formation
  • 相关文献

参考文献1

  • 1刘新月,郝树宏.武乡和信发电有限责任公司1号机大修化学技术诊断报告[R].2009-6091-03.太原:山西电力科学研究院,2009:1-101.

同被引文献20

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...