摘要
通过对锅炉低温过热器管3次泄漏原因进行分析和扩大检查,得出频繁爆管原因是低温过热器管材存在原始制造缺陷所致,并提出了防止缺陷管的产生及其进入安装现场的建议。
Through the analyses on the frequent leakage of low-temperature superheater pipe and expanded inspection,it is concluded that frequent pipe explosion attributes to the pipe' original defects in manufacture,in view of which,suggestions are put forward to avoid the defects in manufacturing and prevent the unqualified pipe being installed.
出处
《山西电力》
2010年第5期50-52,共3页
Shanxi Electric Power
关键词
低温过热器管
原始制造缺陷
管内壁直道
low-temperature superheater pipe
original defects in manufacture
straight part inside pipe wall