摘要
针对300 MW机组凝结水系统的运行现状,提出凝结水系统的节能改造方案,同时,对改造前后的运行情况作出比较,并分析了经济性,改造后效果良好,值得现役同类机组推广。
Based on current operation of 300 MW unit's condensate system,an energy-saving program was proposed.The operation situations of the system before and after the transformation are compared in terms of its energy-saving performance.The result shows that its performance after transformation is worth popularizing in the units of the same type.
出处
《山西电力》
2010年第5期53-55,共3页
Shanxi Electric Power
关键词
凝结水系统
节能
改造
变频器
condensate system
energy saving
transformation
voltage frequency converter