期刊文献+

尿样不同储存方式对氟含量测定值影响的研究 被引量:1

Study of influence on fluorine concentration in different storage ways of urine samples
原文传递
导出
摘要 目的研究尿液在不同条件的储存待检过程中氟含量值的变化。方法常规收集健康成人尿样,在不同条件下储存并分别于采样后3、7、15d、1、3、6个月采用氟离子选择电极法检测氟含量,比较时间、温度以及防腐对尿氟值的影响。结果尿氟含量从第3d至第6个月下降了0.156~1.266mg/L,尿样防腐保存与不防腐保存在-20℃,0~4℃下时有显著性差异,在室温下差异不显著;无防腐剂的尿样比加防腐的尿样氟含量值下降明显;尿氟含量值随保存时间延长均有下降,尤其是在保存1个月后下降明显。结论待检时间、防腐剂的使用、温度都是影响尿氟含量变化的因素,尿样保存的适宜条件应在-20℃、0~4℃下防腐保存,以15d内检测为宜。 Objective To explore the changes of fluorine concentrations of the urine samples in different storage conditions. Methods The urine samples were collected from healthy adults routinely, laid in different conditions and the fluorine content was determined using F - ion selective electrode method in 3 days, 7 days, 15 days, 1 month, 3 months and 6 months after the sampling. The influences of time,temperature and anti - corrosion on the urine fluoride concentration were compared. Results From the first three days to the first 6 months, the fluorine content fell 0. 156 tol. 266 mg/L. The fluorine contents in the urine processed with anti - corrosion and without anticorrosive stored in - 20℃ , 0 to 4℃ have significant difference, no significant difference at room temperature was found. The fluorine content in the urine samples without anti - eon'osion processing decreased obviously than that with anti - corrosion processing. Urine fluorine content declined significantly with time prolonged, especially in the preserved samples at one month later. Conclusions The detecting time, the use of antiseptic and the temperature are all the factors, and they could influence the urine fluorine concentrations. It is suggested that the best method for urine preservation is that the urine sample for fluorine determination should be put in - 20℃ or - 40℃ with anti - corrosion processing and detected in 15 days.
出处 《中国地方病防治》 2010年第5期357-358,共2页 Chinese Journal of Control of Endemic Diseases
关键词 尿 氟含量 储存 影响 Urine Fluorine concentration Storage Influence
  • 相关文献

参考文献3

  • 1姜淑慧 赵锦华 王彦明等.尿氟样品存放影响因素分析.预防医学文献信息,1998,4(2):166-166.
  • 2藏增元 陈喜娜 胡超安等.不同季节人群尿氟含量的变化.中国地方病学杂志,2000,19(5):377-377.
  • 3万桂敏,徐春蓓,莫志亚,刘忠杰,宋丽.尿氟测定样品的采集时间及校正问题[J].中国地方病学杂志,1999,18(2):134-136. 被引量:7

二级参考文献8

  • 1徐春蓓,石玉霞,熊德威,孙玉富.一次随意尿氟水平代替晨尿尿氟水平的可行性研究[J].中国地方病学杂志,1997,16(2):104-105. 被引量:3
  • 2肖明振.尿氟正常值及其排泄规律观察[J].中华口腔科杂志,1982,17(1).
  • 3王鉴清.正常人尿氟排泄规律和影响因素的研究[J].四川医学院学报,1984,15(1):48-48.
  • 4丁俊清.尿氟排泄规律的观察.中华预防医学杂志,1982,16(2):128-128.
  • 5丁俊清,中华预防医学杂志,1982年,16卷,2期,128页
  • 6徐春蓓,中国地方病防治杂志,1997年,16卷,2期,104页
  • 7王鉴清,四川医学院学报,1984年,15卷,1期,48页
  • 8肖明振,中华口腔医学杂志,1982年,17卷,1期

共引文献6

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部