摘要
针对蓄电池供电的便携式工频绝缘试验系统直流/交流变换过程中产生的谐波,应用傅立叶变换分析试验电压波形,针对试验电压中的谐波分量,设计一种有效滤波的有源无源混合型滤波器,试验结果表明滤波效果满足试验标准要求.
To eliminate the harmonics produced by DC/AC conversion of portable power frequency insulation testing system,which take the power from a storage battery,this paper employs the Fourier Transform to analyze testing voltage waveforms. For the harmonics of testing voltage,a kind of effective and active-passive hybrid filter is proposed,the experimental results show that the filter satisfies the demands for testing standard.
出处
《沈阳理工大学学报》
CAS
2010年第3期17-19,共3页
Journal of Shenyang Ligong University
基金
辽宁省教育厅高校重点实验室项目(2008S162)
关键词
工频绝缘试验
便携式
直流/交流变换
谐波分析
滤波
power frequency insulation testing
portable
DC/AC conversion
harmonic analysis
filtering