摘要 根据污水导电的特点,利用与污水相接触的电极进行液位测量,其方法简单实用,具有的优点明显。由于污水的温度和成分不固定,其电导率是变化的,故利用二电极直接测量液体电导来进行液位测量方法不能适用于对污水液位的测量。针对这一问题,提出了一种四电极液位测量方法。通过理论分析和实验验证此方法测量液位不受被测液体电导率变化影响,可用于对温度和成分不固定的污水液位进行测量。 According to the conductivity of sewage, it is simple and practical to use electrodes to measure sewage level. Because the conductivity of sewage varies with composition and temperature, it is not suitable to measure conductance to obtain sewage level by electrodes. To solve this problem, a new technique is presented to measure liquid level by four electrodes. The theoretical analysis and experiment results indicate that the liquid conductivity has no influence on the measurement of liquid level by four electrodes. The new technique is suitable for the level measurement of sewage which changes in temperature and composition.
出处 《传感器与微系统》 CSCD 北大核心 2010年第10期43-45,48,共4页 Transducer and Microsystem Technologies
基金 江苏省高校自然科学基金资助项目(09KJB120003)
关键词 污水 液位测量 液位传感器 四电极方法 sewage level measurement liquid level sensoi four-electrode method
  • 相关文献

参考文献12

  • 1佐藤浩一,梗本清.电阻式液位检测装置:中国发明专利,CN1386191[P].2002-12-18.
  • 2伊利诺斯器械工程公司(美国).电阻式液位检测和控制系统:中国发明专利,CN1296166[P].2001-05-23.
  • 3王晓峰.一种测量导电液体的方法:中国发明专利,CN1362616[P].2002-08-07.
  • 4李旺兴,肖方祥.导电液体液位测量装置:中国发明专利,CN1776376[P].2006-05-24.
  • 5李云飞,颜友钧.智能污水液位仪的研制[J].微电子学与计算机,2004,21(6):132-134. 被引量:1
  • 6Casanella R, Casas O. Continuous liquid level mea-surement using a linear electrode array [ J ]. Meas Sci Technol, 2007,18: 1859 -1866.
  • 7李斌,卫开夏.导电性液体液位测量方法及系统:中国发明专利,CN101025371[P].2007-08-29.
  • 8姜常珍,孙永进,徐立军.电阻层析成像激励电极加权研究[J].天津大学学报(自然科学与工程技术版),2002,35(3):348-353. 被引量:3
  • 9蔡武昌,马中元.电磁流量计[M].北京:中国石化出版社,2005.
  • 10Shercliff J A. The theory of electromagnetic flow measurement [ M ]. Cambridge :The University Press, 1962.

二级参考文献18

  • 1张涛,徐苓安,王竟,杨惠连.计算法计量不满管污水流量的研究[J].仪器仪表学报,1996,17(1):14-18. 被引量:1
  • 2蔡武昌,马中元等.电磁流量计[M].中国石化出版社,2005.
  • 3Blake Doney, ABB Automation, Inc. EMF Flow Measurement in Partially Filled Pipes[J]. Sensors ,October, 1999:65.
  • 4Ramon Casanella,Oscar Casas. Continuous Liquid Level Mea- Surement Using a Linear Electrode Array [J]. Meas. Sci. Technol, 2007 : 1859-1866.
  • 5O' sullivan V T. Performance of an Electromagnetic Flow-Me ter with Six Point Electrodes[J]. Phys E: Sci Instrum, 1983, 16(12) : 1183-1188.
  • 6Shercliff J A. The Theory of Electromagnetic Flow Measure-Ment[M]. Cambridge: The University Press,1962.
  • 7Zhang Xiao-Zhang. The Virtual Current of an Electromagnetic Flow Mter in Partially Filled Pipes[J]. Meas. Sci. Technol:9 (1988) 1852-1855.
  • 8Gorgenyi, L. Sujbert, I. Bogar, K. Molnar, and T. Dabdczi. DSP-bassed Electromagnetic Flowmeter with Sinusoidal Excitation[C]// IMTC2005-Instrumentation and Measurement Technology Conference. Ottawa, Canada, May,2005 : 17-19.
  • 9李斌,卫开夏.导电性液体液位测量方法及系统[P].中国发明专利:200710037413.7
  • 10[1]Ma Yixin.Electrical resisrance tomography and its application to bubbly two-phase flow measurement.[D].Tianjin:Tianjin University,1999.

共引文献12

同被引文献18

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部