摘要 With the development of analytical instrumentation to minimization,integration and automation,the microfluidic chips,which are more integrated,complex and diversified,have been applied widely on the manufacturing of analytical instrumentation.However,the present photolithography-based microfabrication technology,which is only able to pattern microchannels with simple inside structures,can not follow the rapid development of requirements.For solving the problem,a fabrication method based on the restricting effect of laminar flow is proposed for the micro etching on isotropic substrates.Experiments were conducted inside glass-based microchannels,in which certain etchant was used to form complicated microstructures.The flow parameters' effects on the aspect ratio,side wall profile and etching rate were revealed by the experiments.The experimental results reveal that the topography of micro structures patterned with the restricted flow etching method is mainly determined by the flowrates of separator and etchant.The computational fluid dynamics(CFD) model on the interface between multiple streams was established for the etching process,and analysis on the causes of various micro topographies was conducted based on the CFD simulation results.The experimental data consisted with the simulation results very well.The investigation depicted in this paper indicate that the flow restricted etching method provides sufficient references for the research and understanding on the mass transport at the liquid-liquid surface in the microchannel and can be used to pattern complex micro structures with high aspect ratios,meantime,it greatly enriches the microfabrication technology for microfluidic chips. With the development of analytical instrumentation to minimization,integration and automation,the microfluidic chips,which are more integrated,complex and diversified,have been applied widely on the manufacturing of analytical instrumentation.However,the present photolithography-based microfabrication technology,which is only able to pattern microchannels with simple inside structures,can not follow the rapid development of requirements.For solving the problem,a fabrication method based on the restricting effect of laminar flow is proposed for the micro etching on isotropic substrates.Experiments were conducted inside glass-based microchannels,in which certain etchant was used to form complicated microstructures.The flow parameters' effects on the aspect ratio,side wall profile and etching rate were revealed by the experiments.The experimental results reveal that the topography of micro structures patterned with the restricted flow etching method is mainly determined by the flowrates of separator and etchant.The computational fluid dynamics(CFD) model on the interface between multiple streams was established for the etching process,and analysis on the causes of various micro topographies was conducted based on the CFD simulation results.The experimental data consisted with the simulation results very well.The investigation depicted in this paper indicate that the flow restricted etching method provides sufficient references for the research and understanding on the mass transport at the liquid-liquid surface in the microchannel and can be used to pattern complex micro structures with high aspect ratios,meantime,it greatly enriches the microfabrication technology for microfluidic chips.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2010年第5期560-567,共8页 中国机械工程学报(英文版)
基金 supported by National Natural Science Foundation of China (Grant No.50705081,Grant No.50675202)
关键词 MICROFLUIDICS ETCHING computational fluid dynamics(CFD) LAMINAR microfluidics etching computational fluid dynamics(CFD) laminar
  • 相关文献

参考文献17

  • 1DITTRICH P S, TACHIKAWA K, MANZ A. Micro total analysis systems: Latest advancements and trends[J]. Anal. Chem., 2006, 78:3 887-3 908.
  • 2WHITESIDES G M. The origins and the future of microfluidics[J]. Nature, 2007, 442: 368-373.
  • 3PAUL K E, BREEN T L, HADZIK T, et al. Imaging patterns of intensity in topographically directed photolithography[J]. J. Vac. Sci. Technol. B, 2005, 23(3): 918-925.
  • 4HOWLADER M M R, SUEHARA S, SUGA T. Room temperature wafer level glass/glass bonding[J]. Sensors and Actuators A, 2005, 127(1): 31-36.
  • 5VERPOORTE E, ROOIJ N F D. Microfluidics meets MEMS[J]. Proceedings of the IEEE, 2003, 91(6): 930-953.
  • 6LEE G B, KUO T Y, WU W Y. A novel micromachined flow sensor using periodic flapping motion of a planar jet impinging on a V-shaped plate[J]. Experimental Thermal and Fluid Science 2002, 26(5): 435-444.
  • 7WOUDEN E J V, HEUSER T, HERMES D C, et al. Field-effect control of electro-osmotic flow in microfluidic networks[J]. Colloids and Surfaces A: Physicochem, Eng. Aspects. 2005, 267(1-3): 110-116.
  • 8KIM1 K, PAR1 S, LEE1 J B, et al. Rapid replication of polymeric and metallic high aspect ratio microstructures using PDMS and LIGA technology[J]. Microsystem Technologies, 2002, 9(1-2): 5-10.
  • 9MALEK C K, SAILE V. Applications of LIGA technology to precision manufacturing of high-aspect-ratio micro-components and systems[J]. Microelectronics Journal, 2004, 35(2): 131-143.
  • 10URBANSKI J P, THIES W, RHODES C, et al. Digital microfluidics using soft lithography[J]. Lab on a Chip, 2006, 6: 96-104.

同被引文献4

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部