期刊文献+

固定床鼓泡反应器的流型与压降的瞬态表征 被引量:2

Transient Characterizations of Flow Pattern and Pressure Drop in a Fixed-Bed Bubble-Column Reactor
下载PDF
导出
摘要 采用高采集频率的差压传感器及A/D转换器,对固定床鼓泡反应器的瞬时压降数据进行了采集,建立了反应器内的流型识别方法,并通过电容层析成像仪(ECT)对不同流型的气含率的瞬态特征进行了研究。结果表明:不同流型内压降信号的波形、概率密度分布及功率谱密度分布特点差异显著,瞬态气含率亦存在不同特点;随着气液相流速的增加,床层压降梯度逐渐上升;根据实验数据修正的Larachi关联式及Khan和Varma关联式可较好地预测中等塔径(D=280 mm)的固定床鼓泡反应器的摩擦压降,均方根偏差分别为18.0%与14.5%。 A differential pressure sensor and an A/D converter with high frequency were employed to collect transient pressure drop data in a fixed-bed bubble-column reactor.Methods were established to identify the flow patterns in the reactor.The ECT(electrical capacitance tomography)system was employed to investigate transient characteristics of gas holdup in different flow regimes.The waveforms,probability density distributions and power spectrum density distributions of pressure drops are significantly different in various flow regimes.So do transient gas holdups.The bed pressure drop gradient increases with the increase of gas and liquid flow rates.Comparison between experimental data and estimation shows that the revised Larachi's relationship and Khan and Varma's relationship can be used to predict frictional pressure drops in fixed-bed bubble-column reactors of medium diameter(280 mm) with an averaged deviation of 18.0% and 14.5%,respectively.
出处 《华东理工大学学报(自然科学版)》 CAS CSCD 北大核心 2010年第5期610-616,共7页 Journal of East China University of Science and Technology
关键词 固定床反应器 填料鼓泡床 气液两相流 压降关联 fixed-bed reactor packed bubble-column gas-liquid two-phase flow pressure drop correlation
  • 相关文献

参考文献15

  • 1ShahYT.气液固反应器设计[M].北京:烃加工出版社,1989:160-183.
  • 2Ford L H. Multiphase flow through porous media with special reference to the turbulent regime [D]. London:University of London, 1960.
  • 3Sadda M Y. Fluid mechanics of cocurrent two phase flow in packed beds, Pressure drop and liquid holdup studies[J].Periodica Polytechnia-Chemical Engineering, 1975, 19: 317- 337.
  • 4Turpin J L, Huntington R L. Predictions of pressure drop for two-phase two-component cocurrent flow in packed beds [J]. AIChE Journal,1967,13(2) :1196-1202.
  • 5Khan A,Khan A A,Varma Y B G. Flow regime identification and pressure drop in cocurrent gas liquid upflow through packed beds [J]. Bioprocess Engineering, 1997,16 : 355-360.
  • 6Murugesan T,Sivakumar V. Pressure drop and flow regimes in cocurrent gas-liquid upflow through packed beds [J].Chemical Engineering Journal, 2002,88 (1-3) 233-243.
  • 7Khan A,Khan A A,Varma Y B G. Prediction of two-phase frictional pressure drop for the concurrent gas and Newtonian liquids upflow through packed beds [J]. Chemical Engineering & Technology,2002,25(1) :51-55.
  • 8Larachi F,Wild G,Laurent A,et al. Influence of gas density on the hydrodynamics of cocurrent gas liquid upflow fixed bed reactors[J]. Industrial & Engineering Chemistry Research, 1994,33(3)519-525.
  • 9Sindhu H,Sai P S T. A model for pressure drop and liquid saturation in gas-liquid cocurrent upflow through packed bed [J]. Chemical Engineering Journal,2003,93(2) : 135-142.
  • 10戴俊.气—液—固三相并流体系的流型识别[J].华南理工大学学报(自然科学版),1994,22(2):11-17. 被引量:1