磁共振Propeller技术在颅脑MR成像中的临床应用价值 被引量:2

Application of propeller MRI in brain imaging
原文传递
导出
摘要 目的探讨磁共振螺旋桨(propeller)成像技术在临床上的应用价值。方法利用常规序列及propeller技术对35例躁动或有固定金属异物的患者行颅脑磁共振检查。对使用propeller技术前后的快速自旋回波T2加权像序列(T2WI)、液体衰减反转恢复序列(FLAIR)、扩散加权序列(DWI)的图像进行比较。结果 35例应用propeller技术进行T2WI、Flair、DWI成像消除了因运动、金属异物引起的伪影,均获得了满意图像。结论使用propeller技术进行T2WI、Flair、DWI扫描能明显消除患者因运动或金属异物造成的伪影,可生成高分辨率、无伪影、具有临床诊断意义的理想图像。 Objective To study the clinical value of application of the propeller MRI in brain imaging.Methods Brain MRI using propeller technique was performed and T2WI,Flair,DWI sequence were recorded in 35 patients with head diseases who moved during examination or had fixed metal implants.The images were compared before and after the use of T2WI,Flair and DWI.RusultsArtifacts were remarkably reduced after treated with propeller technigue in 35 cases and satisfied MR images were obtained.Conclusion The combined use of peopeller technigue and T2WI,Flair,DWI can obviously remove artifacts produced by movements or metal body.
出处 《江苏医药》 CAS CSCD 北大核心 2010年第18期2137-2139,I0001,共4页 Jiangsu Medical Journal
关键词 磁共振成像 螺旋浆成像技术 Magnetic resonance imaging Propeller technique
  • 相关文献

参考文献9

  • 1俎栋林.磁共振成像学[M].北京:高等教育出版社,2004.101-103,241-243,271-274,507-529.
  • 2Forbes KP, Pipe JG, Karis JP, et al. Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences[J].AJNR, 2003,24(5) 794-798.
  • 3Nishimua DG, Irarrazabal P, Meyer CH. A velocity k-space a-ralysis os flow effects in echo-planar and spiral imagine[J]. Magn Reson Med, 1995,33 (4) : 549-556.
  • 4Pipe JG. Motion correction with propeller MRI;application to head motion and free-breathing cardiac imaging [J]. Magn Reson Med, 1999,42(5) : 963 -969.
  • 5Forbes KP, Pipe JG, Bird CR, et al. Propeller MRI: clinical testing of a novel technique for quantification and compensation of head motion[J]. Magn Reson Med, 2001,14 (3) : 215- 222.
  • 6杨涟,周京民.低场磁共振弥散加权成像在急性、超急性脑梗死影像诊断中的应用[J].江苏医药,2005,31(6):478-478. 被引量:4
  • 7Forbes KP, Pipe JG, Karis JP. Improved image quality and detection of acute cerebral infaretion with propeller diffusion weighted MR imageing[J].Radiology, 2002, 225 (2):551- 555.
  • 8戈明媚,王秋良,刘志钦,刘晓林,廖玉珍,孙玮,孙楠,张英魁.MR螺旋桨扫描技术在消除伪影方面的临床应用[J].中华放射学杂志,2006,40(2):208-212. 被引量:37
  • 9周学军,曹亮.螺旋桨技术及其在头部磁共振扫描中的应用[J].医疗设备信息,2006,21(9):91-93. 被引量:11

二级参考文献14

  • 1Nishimura DG,Irarrazabal P,Meyer CH.A velocity k-space analysis of flow effects in echo-planar and spiral imaging.Magn Reson Med,1995,33:549-556.
  • 2Glover GH,Pauly JM.Projection reconstruction techniques for reduction of motion effects in MRI.Magn Reson Med,1992,28:275-289.
  • 3Meyer CH,Hu BS,Nishimura DG,et al.Fast spiral coronary artery imaging.Magn Reson Med,1992,28:202-213.
  • 4Ehman R,Felmlee J.Adaptive technique for high-definition MR imaging of moving structures.Radiology,1989,173:255-263.
  • 5Ordidge RJ,Helpern JA,Qing ZX,et al.Correction of motional artifacts in diffusion-weighted MR images using navigator echoes.Magn Reson Imaging,1994,12:455-460.
  • 6Sachs T,Meyer CH,Irarrazabal P,et al.The diminishing variance algorithm for real-time reduction of motion artifacts in MRI.Magn Reson Med,1995,34:412-422.
  • 7Pipe JG.Motion correction with PROPELLER MRI:application to head motion and free-breathing cardiac imaging.Magn Reson Med,1999,42:963-969.
  • 8燕树林 曾祥阶.医学影像技术学全科纲要及考题解[M].武汉:湖北科学技术出版社,1999.247-251.
  • 9Pipe JG.Motion correction with PROPELLER MRI:application to head motion and free-breathing cardiac imaging[J].Magn Reson Med,1999,42:963-969.
  • 10尹建忠译.MRI基础[M].天津:天津科技翻译出版公司出版,2004.233.