摘要 荧光剂作为喷雾实验常用的示踪剂,其回收率对实验结果的准确性至关重要。设计了荧光示踪剂回收率影响因素的实验方案,用若丹明WT和荧光素钠作为荧光示踪剂,分别在不同稀释液和洗取液、气象条件、遮盖率、采样时间和沉积载体上测试荧光示踪剂回收率的变化情况。结果表明,在单因素试验中,其他条件相同的情况下,若丹明WT在典型阴天的回收率较高;荧光示踪剂回收率随遮盖率增加而增加;随采样时间增加而降低;滤纸更适宜作为沉积载体。 The fluorescent is usually used as tracers for spraying deposit analysis in pesticide application study.The recovery rate of the tracers is significant for a reasonable explanation of the spraying performance.Experimental scheme was designed in this work and fluorescent was used as tracers.The scheme comprised of a few spraying factors and different environmental conditions.Rhodamine WT and fluorescein sodium were used for the recovery rate tests and weather condition,shading rate,sampling times and sampler feathers were considered as constraints.The experiments shown,on the condition of the same shading rate,sampling times and samplers,recovery rate of Rohdamine WT was higher than fluorescein sodium.If sampling time was fixed with the same deposition carrier,the increase of shading rate would increase the recovery rate of fluorescent tracer.If shading rate and deposition carriers were kept same,the increase of sampling time would decrease the recovery rate of fluorescent tracers.On the condition of the same shading rate and sampling time,filter papers were more suitable deposition carrier comparing to silver papers.
出处 《农业机械学报》 EI CAS CSCD 北大核心 2010年第10期54-57,85,共5页 Transactions of the Chinese Society for Agricultural Machinery
基金 国家"863"高技术研究发展计划资助项目(2008AA100905) "十一五"国家科技支撑计划资助项目(2007BAD89B04)
关键词 喷雾 荧光示踪剂 回收率 若丹明WT 荧光素钠 Spraying Fluorescent tracer Recovery rate Rohdamine WT Fluorescein sodium
  • 相关文献

参考文献14

  • 1Cayley G R, Griffiths D C Huhne P J, et al. Tracer techniques for the comparison of sprayer performance [ J]. Crop Protection, 1987, 6(2): 123-129.
  • 2刘淑芳,陈致国,金崇君.荧光猝灭效应的温度特性研究[J].黑龙江商学院学报,1997,13(1):46-49. 被引量:3
  • 3Koo Y M, Young S C, Kuhlman D K. Flew characteristics of injected concentrates in spray booms[ C]//ASAE Paper No. 87 - 1 602, 1987.
  • 4宋坚利,何雄奎,杨雪玲.喷杆式喷雾机雾流方向角对药液沉积影响的试验研究[J].农业工程学报,2006,22(6):96-99. 被引量:31
  • 5宋淑然,洪添胜,孙道宗,朱余清,彭孝东.风送式喷雾机变速喷雾雾滴沉积试验[J].农机化研究,2009,31(1):166-169. 被引量:14
  • 6Smart P L, Laidlaw I M S. Evaluation of some fluorescent dyes for water tracing[ J]. Water Resources Research, 1977, 13(1): 15-33.
  • 7Pouliquen H, Algoet M, Buchet V, et al. Acute toxicity of fluorescein to turbot (scophthalmus maximus) [ J]. Veterinary and Human Toxicology, 1995, 37(6): 527-529.
  • 8Wang H, Lu L, Zhu S, et al. The phototoxicity of xanthene derivatives against Escherichia coli, staphylococcus aureus, and Saccharomyces cerevisiae[J]. Current Microbiology, 2006, 52( 1 ) : 1 - 5.
  • 9Carre J, Joyeux M, Montiel A. Health risks associated with fluorescent tracers used in hydrology [ J ]. Environnement, Risques et Sante, 2007, 6(6) : 443 -452.
  • 10Ikeya T, Horimoto N, Kashino Y. A practical method for sensitive determination of the fluorescent water-tracer uranine by reversed phase HPLC under alkaline conditions [ J ]. Talanta,2009, 79 ( 3 ) : 818 - 823.

二级参考文献42

  • 1张宝棣,王继波,刘玉兰,田松龄.荧光素钠注射液荧光猝灭的研究[J].光谱学与光谱分析,1994,14(3):105-110. 被引量:7
  • 2康灿,杨敏官,罗惕乾,王晓英,高正平.高压静电喷洒机的试验[J].江苏大学学报(自然科学版),2007,28(3):197-200. 被引量:11
  • 3王晓英,罗惕乾,沙毅,王正,高正平.双流体喷嘴荷电雾化特性[J].江苏大学学报(自然科学版),2007,28(4):328-331. 被引量:22
  • 4林明远.风送喷雾80年代国内外农村新技术[M].北京:农村读物出版社,1984.
  • 5Jones K M, Boundl S A, Oakford M J. Spray application technology [ J ]. Plant Growth Regulation, 2000 ( 31 ) : 173 - 181.
  • 6Paul E Sumner. Experiences with pecan air blast sprayers [ R]. 2004 SAE Annual Meeting,2004.
  • 7Salyani M. Optimization of deposition efficiency for air blast sprayers[ J]. Transactions of the ASAE, 2000,43 (2) :247 - 253.
  • 8Franz E, Bouse L F, Carlton J B,et al. Aerial spray deposit relations with plant canopy and weather parameters [ J ]. Transaction of the ASAE, 1998,41 (4) : 959- 966.
  • 9Salyani M, Fox R D. Evaluation of spray quality by oil and water- sensitive papers [ J ]. Transaction of the ASAE, 1999,42( 1 ) : 37 -43.
  • 10Franz E, Bouse L F, Carlton J B, et al. Aerial spray deposit relations with plant canopy and weather parameters [ J ]. Transaction of the ASAE, 1998,41 (4) :959 - 966.

共引文献106

同被引文献33

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部