期刊文献+

正畸种植体支抗稳定性的研究进展 被引量:1

下载PDF
导出
摘要 种植体支抗在临床应用日益成熟。其中组织学分析是研究种植体支抗稳定性的重要方法之一。作者通过文献回顾,从组织学方面概括出种植体支抗的愈合方式及其稳定性的相关影响因素。
出处 《北京口腔医学》 CAS 2010年第5期298-300,共3页 Beijing Journal of Stomatology
  • 相关文献

参考文献38

  • 1Degushi T,Takamo-Yamamoto T,Kanomi r,et al.The use small titanium screws for orthodontic anchorage.J Dent Res,2003,82(5):377-381.
  • 2Wu J,Bai YX,Wang BK.Biomechanical and histomorphometric characterizations of osseointegration during mini-screw healing in rabbit tibiae.Angle Orthod,2009,79(3):558-563.
  • 3Wu XP,Deng F,Wang Z,et al.Biomechanical and histomorphometric analyses of the osseointegration of microscrews with fifferent surgical techniques in beagle dogs.Oral Surg Oral Med Oral Pathol Oral radiol Endod,2008,106(5):644-650.
  • 4Berglundh T,Abrahamsson I,Lang NP,et al.De novo alveolar bone formation adjacent to endosseous implants.Clin Oral Implants Res,2003,14(3):251-262.
  • 5吴晶,白玉兴,王邦康,高晓辉.微型支抗种植钉愈合期骨结合状态的组织学观察[J].北京口腔医学,2005,13(4):228-230. 被引量:35
  • 6王航,梁星,唐思青,吕丹.正畸支抗种植体骨整合与稳定性的实验研究[J].中华口腔医学杂志,2000,35(2):99-101. 被引量:27
  • 7Vande Vannet B,Sabzevar MM,Wehrbein H,et al.Osseointegration of minisrews;a histomorphometric,evaluation.Eur J Orthod,2007,29(5):437-442.
  • 8Luzi C,Verma C,Melsen B.Immediate loading of orthodontic miniimplants:a histomorphometric evaluation of tissue reaction.Eur J Orthod,2009,31(1):21-29.
  • 9Robert WE,Helm FR,Marshall KJ,et al.Rigid endosseous implants for orthodontic and orthopedic anchorage.Angle Orthod,1989,59(4):247-256.
  • 10Kim JW,Baek SH,Kim TW,et al.Comparison of stability between cylindrical and conical type mini-implants.Mechanical and histological properties.Angle Orthod,2008,78(4):692-698.

二级参考文献45

  • 1寻春雷,曾祥龙,王兴.自攻型微钛钉种植体增强磨牙支抗的临床应用研究[J].中华口腔医学杂志,2004,39(6):505-508. 被引量:72
  • 2张扬,张丹,冯翠娟.微小种植体正畸支抗生物力学的三维有限元分析[J].上海口腔医学,2005,14(3):281-283. 被引量:33
  • 3姜晓红,张扬,刘继辉,徐延.微型种植体支抗在正畸治疗双颌前突中切牙及磨牙位置变化的研究[J].中国医科大学学报,2006,35(4):395-396. 被引量:14
  • 4吕丹 梁星.种植单冠支抗关闭牙列间隙-例[J].华西口腔医学杂志,1999,17:165-165.
  • 5Tseng YC, Hsieh CH, Chen CH et al. The application of mini-implants for orthodontic anchorage. Int J Oral Maxillofac Surg 2006;35(8):704-707.
  • 6Park HS, Jeong SH and Kwon OW. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2006; 130:18-25.
  • 7Freire JN, Silva NR, Gil JN,el aLHistomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage.Am J Orthod Dentofacial Orthop 2007;131(6):704.e1-9.
  • 8Gedrang T, Bourauel C,Kobel C,et al.Tree-dimensional analysis of endosseous palatal implants and bone after vertical,horizontao,and diagonal force application.European J Orthodontics Orthdonties 2003;25:109-115.
  • 9Motoyoshi M, Yano S, Tsuruoka. et al. Biomechanical effect of abutment on stability of orthodontic mini-impalnt.A finite element analysis. Clin.Oral Impl. Res 2005; 16; 480-485.
  • 10Murphy WH, Williams KR, Gregory MC. Stress in bone adjacent to dental implant. J Oral Rehabil 1995; 22 (12): 897 - 903.

共引文献83

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部