期刊文献+

胶束增溶分光光度法测定食品中的铝含量 被引量:5

Determination of aluminum content in food by optimized micellar solubilization spectrophotometry
原文传递
导出
摘要 实验建立了Al-CAS-CPC-OP胶束增溶分光光度法。在pH6.55的6次甲基四胺缓冲溶液中,配合物的最大吸收波长为630nm,表观摩尔吸收系数为1.49×105L/mol·cm,Al(Ⅲ)的浓度在0~0.2μg/mL范围内符合比耳定律。利用该方法对食品中的铝含量进行测定,加标回收率为93.7%~102.0%,测定结果的相对标准偏差为2.3%~6.8%。 The aluminum content in foods was determined in the Al (Ⅲ)-CAS-CPC-OP system by micellar solubilization spectrophotometry. Simplex optimization design was carried out to create an optimal experimental condition. The Beer's law was obeyed in the range of 0~0.2 μg/mL for Al (Ⅲ) in medium of pH 6.55 at 630 nm, with apparent molar absorptivity of 1.49×10^5 L/mo·lcm. The method has been used to the determination of aluminum in food with the RSD of 2.3%~6.8% and the recovery of 93.7%~102.0%.
出处 《食品科技》 CAS 北大核心 2010年第10期294-296,300,共4页 Food Science and Technology
关键词 胶束增溶 分光光度法 单纯形优化实验设计 micellar solubilization spectrophotometry aluminum simplex optimization design
  • 相关文献

参考文献5

二级参考文献16

共引文献49

同被引文献29

  • 1张珂,梁晶辉,苏敏.石墨炉原子吸收法测定化妆品中的铝[J].中国公共卫生,2004,20(10):1155-1155. 被引量:11
  • 2Gao X, Zheng H, Shang GQ, et al. Colorimetric detection of fluor- ide in an aqueous solution using Zr(Ⅳ)-EDTA complex and a no- vel hemicyanine dye[J]. Talanta,2007 ,73 :770 - 775.
  • 3Mhatre SN, Iyer RK, Moorthy PN, Characterization of aluminium complexes in tea extract. Part Ⅰ- 27A1 NMR studies [J]. Mag Re- son Chem,1993 ,31:169 - 175.
  • 4卫生部.GB/T5009.182-2003面制食品中铝的测定[S].北京:中国标准出版社,2003.
  • 5DE AMORIM F R, BOF C, FRANCO M B, et al. Comparative study of conventional and multivariate methods for aluminum determination in soft drinks by graphite furnace atomic absorption spectrometry [ J ]. Microchem J, 2006, 82: 168-173.
  • 6ARVAND M, ASADOLLAHZADEH S A. Ion-selective electrode for aluminum determination in pharmaceutical substances, tea leaves and water samples [ J ]. Talanta, 2008, 75 : 1046-1054.
  • 7LI Qiong, WANG Lirong, XI Danli, et al. Determination of trace aluminum in foods by stripping voltammetry[~]. Food Chem, 2006, 97: 176-180.
  • 8国家质量监督检验检疫总局.GB/T23374--2009食品中铝的测定电感耦合等离子体质谱法[S].北京:中国标准出版社,2009.
  • 9ALBEND|N G, M~NUEL-VEZ M P, MORENO C, et al. Reverse flow-injection manifold for spectrofluorimetric determination of aluminum in drinking water [ J ]. Talanta, 2003, 60, 425-431.
  • 10AL-KINDY S M Z, AL-GHAMARI S S, SUL1MAN F E O. A sequential injection method for the fluorimetric determination of aluminum in drinking water using 8- hydroxy-7-(4-sulfo-l-naphthylazo)-5-quinoline sulfonic acid[J]. Spectrochimica Acta Part A, 2007, 68: 1174-1179.