高温高压屏蔽电泵起动堵转分析

Analysis on the Locked Rotor Phenomenon during Starting of the High-temperature & High-pressure Shield Pump
下载PDF
导出
摘要 对高温高压屏蔽电泵堵转现象进行分析,得出电泵发生堵转现象是因下止推轴承装配工作面外凸内凹,轴承类似碟盘状,与推力盘配合形成了楔角,局部发生摩擦。在系统压力作用下,工作面形成局部负压,导致轴承摩擦副比压力增大,摩擦阻转矩达到并超过起动转矩。 The locked rotor phenomenon of the high-temperature and high-pressure shield pump was analyzed and the cause of it was revealed that working surface of the downward thrust bearing projected outward and reentered entad, shaped like a small plate which formed a wedge angle and resulted in dry friction partially. With the function of the system pressure, mina pressure was established on the working surface, i.e. specific pressure of the friction was increased and friction torque reached or exceeded the value of start torque.
出处 《电机技术》 2010年第5期45-47,共3页 Electrical Machinery Technology
关键词 高温高压屏蔽电泵 堵转 流体润滑 止推轴承 High-temperature and high-pressure shield pump Locked rotor Liquid lubricant Thrust bearing
  • 相关文献

参考文献1

  • 1机械设计手册编委会.机械设计手册(3版).机械工业出版社,2004.