广州某展馆空调冷却塔水军团菌污染状况调查 被引量:2

Legionella Pneumophila Pollution Status of Cooling Tower Water in the Exhibition Hall of Guangzhou
原文传递
导出
摘要 目的了解广州某展馆军团菌污染状况,提出相应的防制对策。方法对2008-2009年在广州某展馆采集的44份空调冷却塔水样进行军团菌的分离培养与鉴定,并对检测结果进行统计学分析。结果 44份水样中分离出15株军团菌,军团菌阳性检出率为34.1%。展馆A、B、C区的空调系统运行年限不同,但军团菌阳性检出率差异无统计学意义(2χ=0.143,P>0.05)。军团菌检出率在春秋两季差异有统计学意义(2χ=4.130,P<0.05),其中秋季军团菌检出率较高,为50.0%,而春季检出率则相对较低,为20.8%。结论广州某展馆空调冷却塔水军团菌污染状况较为严重,对其危险性应引起高度重视并进行有效控制,以防止军团病的暴发流行。 Objective To investigate Legionella pneumophila pollution status of air-conditioning cooling tower water in the exhibition hall of Guangzhou,find out necessary control measures.Methods Legionella pneumophila of 44 cooling tower water samples were isolated culture and identified.Results 15(34.1%) of 44 samples were isolated Legionella pneumophila.There was no significant difference in isolation rate of Legionella pneumophila in spite of different running years of air-conditioning system in A,B and C areas.There was significant difference in isolation rate of Legionella pneumophila in spring and autumn,the isolation rate of Legionella pneumophila in autumn(50.0%) was relatively higher than that in spring(20.8%).Conclusion There is serious Legionella pneumophila pollution of cooling tower water in the exhibition hall of Guangzhou,so attention should be paid to these hazard factors.Effective measures should be taken to prevent the outbreak of Legionella pneumophila.
出处 《中国卫生工程学》 CAS 2010年第5期362-363,共2页 Chinese Journal of Public Health Engineering
关键词 军团菌 空调 冷却塔水 展馆 Legionella pneumophila Air Conditioning Cooling tower water Exhibition hall
  • 相关文献

参考文献7

二级参考文献60

共引文献129

同被引文献101

  • 1于凌琪,王书梅,张致一,王菲,薛志明,刘洪亮.天津市四星级以上宾馆集中空调通风系统微生物污染调查[J].环境与健康杂志,2008,25(1):65-66. 被引量:1
  • 2刘玲,刘一君,郭小玲,沈峻.湖北省公共场所卫生状况调查[J].公共卫生与预防医学,2007,18(1):90-91. 被引量:4
  • 3李泉,付洁,马弋,杨晓敏,谢茂慧.湖北省三市集中式中央空调冷却塔水军团菌污染状况调查[J].公共卫生与预防医学,2007,18(2):50-51. 被引量:5
  • 4Sala-Ferr6 MR. Monitoring of biofilm-associated Legionella pneumophila on different substrata in model cooling tower system[J]. Eur J Clin Microbiol Infect Dis, 2009, 28:153-159.
  • 5Freudenmann M, Kurz S, yon Baum H. Interdisciplinary management of a large Legionella outbreak in Germany [ J ]. Bundesgesundheitsbl, 2011,54:1161-1169.
  • 6曹春远,陈前进,张景平,等.龙岩市2006.2010年部分公共场所水体军团菌污染状况调查分析[c]//第二届传染病防控基础研究与应用技术论坛论文集.2011:181-187.
  • 7高建民,李柱锋,老倩群,等.顺德区公共场所集中空调通风系统微生物污染状况调查与分析[J].中外健康文摘,2013,10(19):8-9.
  • 8Robert LS, Benjamin LW, Leslie E L. The influence of rapid onsite evaluation on the adequacy rate of fine-needle aspiration cytology: a systematic review and mela-analysis[J ]. Am J Cli Pathol,2013, 139: 300-8.
  • 9Campesea C,Bitar D,Jarraud S. Progress in the surveillance and control of Legionella infection in France, 1998-2008 [ J ]. Int J Infect Dis, 2011, 15:30-37.
  • 10Walser SM, Gerstner DG, Brenner B.Assessing "the environmental health relevance of cooling towers-a systematic review of legionellosis outbreaks[ J ]. Int J Hyg Environ Health,2014, 217:145-54.

引证文献2

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部