期刊文献+

江苏省输电线路雷击跳闸原因分析及防雷击措施 被引量:4

Cause Analysis of Thunder Outage and Thunder Protection Measures of Transmission Lines
下载PDF
导出
摘要 根据部分有代表性的输电线路的运行统计资料,运用耐雷水平和雷击跳闸率计算公式,查找出导致雷击跳闸率上升的主要原因,并进行理论分析,确定导致雷击跳闸率上升的关键问题.针对这一关键问题进行敏感性分析,提出控制措施.同时,对雷击跳闸率公式可能存在的问题,提出了修正建议. The primary cause for the increase in lightning-stroke trip-out rate is deduced based on the statistical data and computation formula of lightning resisting level and lightning-stroke trip-out rate.Further theoretical analysis is made and the inner key problem of leading to the increase in lightning-stroke trip-out rate is determined.With focus on the inner key problem,the sensitivity analysis is made and the control measures are proposed in a most systematical and thorough manner.Through analyzing the present computation formula of lightning-stroke trip-out rate,the existing problems are figured out and modification suggestions are put forward.
出处 《上海电力学院学报》 CAS 2010年第5期429-433,共5页 Journal of Shanghai University of Electric Power
关键词 输电线路 雷击跳闸 原因分析 防雷措施 transmission line thunder outage cause analysis thunder protection measures
  • 相关文献

参考文献1

  • 1杜澍春,陈维江.(DL/T620-1997)附录B.交流电气装置的过电压保护和绝缘配合[s].北京:中国电力出版社,1997:40-56.

共引文献2

同被引文献32

引证文献4

二级引证文献65

相关作者