期刊文献+

64层CT多平面重组长骨图像质量与检查参数

The Image Quality of Long Bone MPR Reconstruction and Examination Parameters Using 64-slices CT
原文传递
导出
摘要 目的研究64层CT长骨扫描和后处理参数对多平面重组(MPR)图像质量的影响,探讨最佳参数。资料与方法采用64层CT不同的扫描与重组参数获取直接扫描的横断面图像及后处理的横断面及长轴面的MPR图像。对图像质量进行评分,并进行统计学处理。结果对于长骨CT的MPR图像,薄层厚、大螺距的组合优于大层厚、小螺距组合,最佳参数为层厚0.6mm,螺距1.5,重组间隔50%,骨算法重组。结论不同的扫描与后处理参数对长骨CTMPR图像质量有明显影响,上述最佳参数可使64层CT在最短时间内以最小的球管损耗显示最佳的长骨MPR图像。 Objective To study the effect of scanning and postprocessing parameters to the image quality of long bone multi-planar reconstruction by 64-slice CT and to find the optimal parameters. Materials and Methods Different parameters of scanning and post-processing were used to obtain direct-scanning transaction images and post-processing transaction and long-axial MPR images.The images quality was evaluated and compared,the scores were analyzed statistically. Resu-lts For long bone CT MPR images,the parameters of a smaller slice-thickness together with a larger pitch was better than that of a larger slice-thickness together with a smaller pitch,the optimal parameters were slice thickness 0.6 mm,pitch 1.5,reconstruction increment 50%,high-resolution algorithm. Conclusion The quality of long bone CT images can be greatly influenced by scanning and post-processing parameters,and the above optimal parameters make it a reality to get best long bone images in the shortest time with the least X-ray tube exhaustion by 64-slice CT.
出处 《临床放射学杂志》 CSCD 北大核心 2010年第10期1380-1383,共4页 Journal of Clinical Radiology
关键词 骨骼 体层摄影术 X线计算机 参数 图像质量 Skeleton Tomography X-ray computed Parameters Imaging quality
  • 相关文献

参考文献7

  • 1Jager L, Bonell H, Liebl M, et al. CT of the Normal Temporal Bone : Comparison of Multi-and Single-Detector Row CT. Radiology, 2005, 35:33.
  • 2陈海松,柳澄,陈青华.64层CT多向调整多平面重组诊断长骨病变的价值[J].中华放射学杂志,2006,40(2):204-207. 被引量:24
  • 3Murphey MD, Jelinek JS,Temple HT, et al. hnaging of Periosteal Osteosarcoma : Radiologic-Pathologic Comparison. Radiology, 2004, 233:129.
  • 4Murphey MD, Nomikos GC, Flemming DJ, et al. Imaging of Giant Cell Tumor and Giant Cell Reparative Granuloma of Bone:Radiologic-Pathologic Correlation. RadioGraphics, 2001,21 : 1283.
  • 5El-Sheik M,Heverhagen JT, Alfke H, et al. Multiplanar Reconstructions and Three-dimensional Imaging (Computed Rotational Osteo- graphy) of Complex Fractures by Using a C-arm System: Initial Resuits. Radiology ,2001,221:843.
  • 6张伟,龚建平,王可武,朱建兵,钱铭辉.低kV-CT扫描参数的优化设计[J].临床放射学杂志,2008,27(10):1411-1413. 被引量:10
  • 7Pretorius ES, Fishman EK. Volume-rendered three-dimensional spiral CT : musculoskeletal applications. RadioGraphics, 1999,19 : 1143.

二级参考文献20

  • 1谢元忠,李长勤,孔庆奎,王霞.去分化软骨肉瘤的影像分析[J].中华放射学杂志,2004,38(11):1151-1154. 被引量:18
  • 2邓大平,张贵林,朱建国,杜希成.CT检查剂量与防护[J].中国辐射卫生,2004,13(4):309-310. 被引量:8
  • 3Flohr TG,Schaller S,Stierstorfer K,et al.Multi-detector row CT systems and image-reconstruction techniques(Review).Radiology,2005,235:756-773.
  • 4Hu H,He HD,Foley WD,et al.Four multidetector-row helical CT:image quality and volume coverage speed.Radiology,2000,215:55-62.
  • 5Murphey MD,Jelinek JS,Temple HT,et al.Imaging of periosteal osteosarcoma:radiologic-pathologic comparison.Radiology,2004,233:129-138.
  • 6Rydberg J,Buckwalter KA,Caldemeyer KS,et al.Multisection CT scanning techniques and clinical applications(Review).Radiographics,2000,20:1787-1806.
  • 7Klingenbeck-Regn K,Schaller S,Flohr T,et al.Subsecond multi-slice computed tomography:basics and applications.Eur J Radiol,1999,31:110-124.
  • 8Berrington de Gonzalez A, Darby S. Risk of cancer from diagnostic X-ray:estimates for the UK and 14 other countries. Lancet,2004, 363:345
  • 9Kalar MK, Maher MM, Sahani DV, et al. Low-dose CT of the abdomen : evaluation of image improvement with use of noise reduction filters-pilot study. Radiology,2003,228:251
  • 10Mayo JR, Kim K, Mac Donaid SIS, et al. Reduced radiation dose helical chest CT: effect on reader evaluation of structures and lung findings. Radiology ,2004,232:749

共引文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部