Objective:To explore the value of end-tidal carbon doxide(ETCO2)monitoring in intubation with double-lumen endobronchial tube(DLT).Methods:A total of 40 cases with thoractomy due to right lung diseases,at ASA Ⅰ-Ⅲ stage were under anaesthesia by intubation with left DLT(L-DLT).Tube location was determined by auscultation and fibrobronchoscopy(FOB).ETCO2 of bronchus and wave change were observed.Results:As varying DLT position,breath sounds in both sides,monitoring results and wave all changed.Conclusions:ETCO2 monitoring is helpful in guidence and location of DLT.