期刊文献+

ACTIFLO高效澄清池的运行优化研究 被引量:3

Operation Optimization of ACTIFLO Clarifier
原文传递
导出
摘要 针对ACTIFLO澄清池在处理微污染源水运行过程中存在的问题以及节能减排的需要,通过模拟烧杯试验和现场试验相结合的方式对其运行条件和参数进行了优化研究。结果表明,采用回流污泥代替微砂同样能达到较好的沉后水水质;ACTIFLO澄清池第三阶段的搅拌桨转速对沉后水的水质影响很大,低转速下可减少PAM投量、增大污泥回流量,不仅能达到较好的出水水质,而且能达到节能减排的效果。 In order to solve some problems existed during treating the micro-polluted source water in ACTIFLO clarifiers, and to meet the demand for energy-saving and discharge reduction, the operation conditions and parameters of ACTIFLO clarifier were optimized through jar test and field test. The results show that the good quality of sedimentation effluent also can be achieved by recycled sludge instead of micro-sand. The impeller speed in the third stage of ACTIFLO clarifier has great influence on the water quality. When the impeller speed is low, PAM dosage can be reduced, and the flow of recycled sludge can be increased, which achieves excellent water quality and energy-saving and discharge reduction.
出处 《中国给水排水》 CAS CSCD 北大核心 2010年第21期47-50,54,共5页 China Water & Wastewater
基金 科技部科技支撑计划项目(2006BAJ08B06) 国家水体污染控制与治理科技重大专项(2008ZX07421-004)
关键词 ACTIFLO澄清池 微砂 助凝剂 回流污泥 ACTIFLO clarifier micro-sand coagulant aid recycled sludge
  • 相关文献

参考文献7

二级参考文献17

  • 1张素霞,徐扬,刘永康,解乃菊,吴勤,邢晋武,丁明亮,陈晓华.ACTIFLO~微砂加重絮凝斜管高效沉淀技术[J].中国给水排水,2006,22(8):26-31. 被引量:22
  • 2.法国Vivendi Water技术交流资料[Z].,2003年..
  • 3上海市政工程设计研究院.临江水厂扩建工程可行性研究报告[R].,2003,05..
  • 4Victoria Plum,Claus P Dahl.The actiflo method [J].Wat Sci Tech,1998,37(1) :269-275.
  • 5Christian Desjardinsa,Boniface Koudjonoub,Raymond Desjardins.Laboratory study of ballasted flocculation [J].Water Research,2002,36 (4):744-754.
  • 6Procédé et.Installationde Traitement d' eau Décantation Faisant Intervenir du Sable Fin[M].Brevet FrancaisNr 8802288,1991.
  • 7Pujol E,Vullierme M,Drvoton J C,et al.Décanteur actiflo à l'usineneuilly-sur-marne[J].TSM,1993,(11):15 -18.
  • 8Guibelin E,Delsalle F,Binot P.The ACTIFLO(R) Process:A highly compact and efficientprocess to prevent water pollution by stormwater flows[J].Water SciTechnol,1994,30(1):87-96.
  • 9Paffoni C,Delbec M,Millard P,et al.Impact prévisible du traitement des eaux excédentairede temps de pluie par clarifloculation à seine aval[J].TSM,2001,(3):52 -55.
  • 10Fioravanti A,Bourdon F.Décantation primaire à flocs lestés deseaux usées procédé actiflo cas particulier de la station d'épurationde genève-aire Ⅱ[J].L'EAU,L'INDUSTRIE,LES NUISANCES,2004,27 (9):251 -255.