期刊文献+

工业冷却水中除锰、除铁的试验研究 被引量:3

Experiment and Research on the Mn and Fe Removal from Industrial Cooling Water
下载PDF
导出
摘要 研究了无烟煤-石英砂滤料接触氧化法除工业冷却水中锰、铁的工艺条件。滤料粒径05mm~10mm,滤床高800mm(无烟煤、石英砂滤料各400mm),滤速10m/h~12m/h,工作周期96h,反冲洗强度10L/(m2·s),反冲洗时间5min~7min,出水Mn2+浓度为004mg/L以下,去除率可达90%以上,总铁浓度为痕量。 Abstract This paper focuses on the research of a process to remove manganese and iron from the industrial cooling water by contact oxidation process using natural filtering media of anthracite and quartzite. The operating parameters are: size of filTering maTerial 0.5 to 1.0 mm, filtering bed height 800mm, filtering speed 10 to 12 m/h, working cycle 96 hours, backwashing strength 13 L/(m 2·s) and backwashing time 5 to 7 min. In the treated water the residual Mn 2+ concentration is below 0.04mg/L with removal ratio up to 90% and the total Fe is trace level.
出处 《给水排水》 CSCD 北大核心 1999年第6期41-43,共3页 Water & Wastewater Engineering
  • 相关文献

参考文献10

  • 1张杰,杨宏,徐爱军,鲍志戎,李惟.生物固锰除锰技术的确立[J].给水排水,1996,22(11):5-10. 被引量:97
  • 2杨旭鹏.-[J].辽阳石油化工高等专科学校学报,1997,13:46-52.
  • 3李圭白.天然锰砂除铁设备的设计原则[J].给水排水,1975,(1):1-8.
  • 4刘灿生.关于过滤除铁过程中除铁滤料成熟问题的研究[J].哈尔滨建筑工程学院学报,1984,(1):63-69.
  • 5刘灿生,黄毅轩,陈牧民.关于地下水除铁、除锰机理的讨论[J].给水排水,1996,22(10):17-20. 被引量:17
  • 6杨旭鹏,辽阳石油化工高等专科学校学报,1997年,13卷,增,46页
  • 7石振华,城市地下水工程与管理手册,1993年,642页
  • 8李圭白,地下水除铁除锰(第2版),1989年,4页
  • 9刘灿生,哈尔滨建筑工程学院学报,1984年,1期,63页
  • 10李圭白,给水排水,1975年,1期,1页

二级参考文献1