地震区底层带商店建筑合理结构形式的研究 被引量:1

RESEARCHES INTO APPROPRIATE STRUCTURE TYPES OF HIGHRISE BUILDING WITH GROUND FLOOR SHOP IN SEISMIC REGION
下载PDF
导出
摘要 在地震区,底层带商店建筑可采用的结构形式有底部框架剪力墙上部砌体结构、多层内框架结构、多层全框架结构、多层砌体结构等;不应采用底层内框架砖房、底层纯框架砖房等形式。正确选择底层带商店建筑的结构形式,有利于降低工程造价,确保结构安全。 In seismic region,the appropriate structure types of highrise building with ground floor shop are generally as follows:the bottom framed shearing wall and top masonry structure,the multiple storey internally framed structure,the multiple storey completely framed structure,and the multiple storey masonry structure etc.Nevertheless,those structure types such as the bottom internally framed brick building,and the bottom completely framed brick building etc.must be forbidden in seismic region.Consequently,by the appropriate selection of construction type,the costs of these constructions could be considerably reduced and the security of construction could be guaranteed.
出处 《建筑技术》 北大核心 1999年第5期327-329,共3页 Architecture Technology
关键词 底层带商店建筑 结构选择 抗震设防 抗震墙 highrise building with ground floor shop,selection of structure,aseismatic measure,aseismatic wall
  • 相关文献

参考文献3

  • 1设置钢筋混凝土构造柱多层砖房抗震技术规程(JGJ/T13-94),1994年
  • 2龚思礼,建筑抗震设计手册,1994年
  • 3刘大海,高楼结构方案优选,1992年