期刊文献+

用于单电子自旋探测微悬臂梁的制作及端头磁针尖设计 被引量:1

Fabrication of Ultra-Sensitive Cantilever for Single Electron Spin Detection and Design of Magnetic Tip
下载PDF
导出
摘要 提出一种用于单电子自旋探测微悬臂梁的制作方法。采用顶层Si厚度为1μm的SOI硅片,在器件层刻蚀出悬臂梁图形后,利用热氧化将Si梁减薄至0.5μm,同时生成SiO2保护层。在KOH溶液进行体硅刻蚀过程中,以黑蜡和SiO2保护层作为正面保护,之后用溶液置换方法完成埋氧层去除及悬臂梁清洗过程。悬臂梁尺寸为465μm×10μm×0.5μm,室温真空中Q值为23000,在低温环境中可以满足单电子自旋探测要求。分析比较了球体、圆锥体、圆柱体三种磁针尖磁场梯度分布,为磁针尖结构设计提供了依据。 We have designed and fabricated the ultra-sensitive cantilevers for single electron spin detection.A SOI wafer with a 1 μm-thick device layer was used as the fabrication material.The cantilevers were patterned on the device layer,and then thinned to 0.5 μm-thick through thermal oxidation;meanwhile,an oxide protection layer for cantilever was generated.During the bulk silicon etching,the cantilever was protected by black wax and the silicon oxide.The buried oxide layer etching and the cantilever cleaning were both under liquid without pulling it out.The Q factor of a cantilever with 465 μm×10 μm×0.5 μm dimensions is 23 000 in a vacuum chamber at room temperature.It is believed that the cantilever is sensitive enough for single spin detection at low temperature.We simulated the magnetic field of three types of magnet tips,and found that a conical magnet tip shows the strongest field gradient at the near field.
出处 《传感技术学报》 CAS CSCD 北大核心 2010年第10期1399-1402,共4页 Chinese Journal of Sensors and Actuators
基金 中国科学院重大科研装备研制项目(YZ0637) 国家自然科学基金资助项目(50805137)
关键词 磁共振力显微镜 悬臂梁 磁针尖 电子自旋 MRFM cantilever magnetic tip electron spin
  • 相关文献

参考文献12

  • 1Mounce D.Magnetic Resonance Force Microscopy[J].IEEE Instrumentation & Measurement Magazine,2005,8,20-26.
  • 2Ciobanu L,Seeber D A,Pennington C H.3D MR Microscopy with Resolution 3.7 μm by 3.3 μm By 3.3 μm[J].J.Magn.Reson.2002,158:178-182.
  • 3Blank A,Dunnam C R,Borbat P P,et al.High Resolution Electron Spin Resonance Microscopy[J].J.Magn.Reson.2003,165:116-127.
  • 4Rugar D,Budakian R,Mamin H J,et al.Single Spin Detection By Magnetic Resonance Force Microscopy[J].Nature,2004,430:329-332.
  • 5Mamin H J,Poggio M,Degen C L,et al.Nuclear Magnetic Resonance Imaging with 90-nm Resolution[J].Nature nanotechnology,2007,5:301-306.
  • 6Degen C L,Poggio M,Mamin H J,et al.Nanoscale Magnetic Resonance Imaging[J].PNAS,2009,106(5):1313-1317.
  • 7Stowe T D,Yasurnura K,Kenny T W.Attonewton Force DetectionUsing Ultrathin Silicon Cantilevers[J].Appl.Phys.Lett,1997,71(2):288-290.
  • 8Jenkins N E,DeFlores L P,Allen J,et al.Batch Fabrication and Characterizatiou of Ultrasensitive Cantilevers with Submicron Magnetic Tips[J].J.Vac.Sci.Technol.B,2004,22(3):909-915.
  • 9Gysin U,Rast S,Meyer E,et al.Fabrication of Ultrafloppy Single-Crystal Silicon Cantilever for Magnetic Resonance Imaging[C]//Proceedings of the Fourth IEEE Conference on Sermon,2005,2005,269-272.
  • 10Mouaziz S,Dysli A,Brugger J,et al.Highly Sensitive Cantilevers,with and Without Magnetic Tip,for Magnetic Resonance Force Microscopy[C]//14th International Conference on SolidState Sensors,Actuators and Microsystems,2007,1537-1540.

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部