期刊文献+

超声多普勒技术在323例危重症患者颈内静脉穿刺置管术中的应用 被引量:10

Application of Doppler Ultrasound in Internal Jugular Vein Catheterization: Analysis of 323 Critically Ill Patients
原文传递
导出
摘要 目的:探讨超声多普勒技术在危重症患者颈内静脉穿刺置管中的临床应用价值。方法:选取323例预计颈内静脉穿刺困难的危重症患者,在超声引导下行右颈内静脉穿刺置管,记录穿刺时间、一次穿刺置管成功率、二次以上穿刺置管成功率及并发症发生例数。结果:323例患者均在超声引导下行右颈内静脉穿刺置管成功,无一例因穿刺失败改行其他部位中心静脉穿刺。超声多普勒引导穿刺置管操作时间184.6±20.5s。超声多普勒引导一次穿刺置管成功率93%。超声多普勒引导二次以上穿刺置管成功率100%。并发症发生率4.64%。结论:应用超声多普勒技术引导危重症患者颈内静脉穿刺置管,缩短了置管时间,减少了穿刺次数,提高了一次穿刺成功率。 Objective: To investigate the application of doppler ultrasound in critically ill patients with internal jugular vein catheterization. Methods: 323 cases of anticipated difficult internal jugular vein in critically ill patients, the ultrasound guided right internal jugular vein puncture, puncture record time, a success rate of catheterization, more than twice the success rate of catheterization and complications place the number of cases. Results: 323 patients were in the ultrasound guided right internal jugular vein catheterization successfully, no case be diverted to other parts due to puncture failure of central venous puncture. Doppler ultrasound guided catheter placement operation time of 184.6 ± 20.5s. Doppler ultrasound guided puncture an 93% success rate. Doppler ultrasound guided puncture more than twice the success rate of 100%. Complication rate was 4.64%. Conclusion: Doppler ultrasound guided internal jugular vein in critically ill patients cannulated shortened tube time, reducing the number of puncture and improve the success rate of a puncture.
出处 《现代生物医学进展》 CAS 2010年第20期3869-3871,共3页 Progress in Modern Biomedicine
关键词 超声多普勒 引导 颈内静脉穿刺置管术 Doppler ultrasound; Guidance; Internal jugular vein catheterization;
  • 相关文献

参考文献1

  • 1U. Mey,A. Glasmacher,C. Hahn,M. Gorschlüter,C. Ziske,M. Mergelsberg,T. Sauerbruch,I. Schmidt-Wolf. Evaluation of an ultrasound-guided technique for central venous access via the internal jugular vein in 493 patients[J] 2003,Supportive Care in Cancer(3):148~155

同被引文献89

  • 1许荔,何志安.超声引导在颈内静脉穿刺置管困难时的应用价值[J].临床军医杂志,2010,38(6):1047-1048. 被引量:5
  • 2魏新川,魏蔚,李羽.婴幼儿超声预定位与解剖定位颈内静脉穿刺的对比研究[J].中国胸心血管外科临床杂志,2005,12(1):15-18. 被引量:10
  • 3潘农,战微微,孔晓敏,马晓棠,张正贤.超声引导下经外周静脉穿刺中心静脉置管的临床价值[J].中华超声影像学杂志,2005,14(11):870-871. 被引量:41
  • 4黄养能,张茂,杨俭新,吴红波,刘志海,干建新,江观玉.超声定位在急诊ICU患者困难深静脉置管中的应用[J].中华麻醉学杂志,2006,26(11):1047-1048. 被引量:24
  • 5周继如.实用急救医学[M].北京:科学技术文献出版社,2006:1038-1039.
  • 6Oguzkurt L, Tercan F, Kara G, et al. US-guided placement of temporary internal jugular vein catheters: immediate technical success and complications in normal and high-risk patients[J]. Eur J Radiol, 2005, 55(1): 125-129.
  • 7Milling TJ Jr, Rose J, Briggs WM, et al, Randomized, controlled clinical trial of point-of-care limited uhrasonography assistance of central venous cannulation: the Third Sonography Outcomes As- sessment Program(SOAP-3) Trial[J]. Crit Care Med, 2005, 33(8): 1764-1769.
  • 8Mey U, Glasmacher A, Hahn C, et al. Evaluation of an uhra- sound-guided technique for central venous access via the internal jugular vein in 493 patients[J]. Support Care Cancer, 2003, 11(3): 148-155.
  • 9Aponte H, Acosta S, Rigamonti D, et al. The use of tdtrasound for placement of intravenous catheters [J]. AANA J, 2007, 75(3): 212-216.
  • 10Liehtenstein D, Saifi R, Augarde R, et al. The internal jugular veins are asymmetric. Usefulness ofultrasotmd before catheteri- zation [J]. Intensive Care Med, 2001, 27 (1):301.